Norsat International Inc.
Norsat MDX400ANEG-XF-S MEDIAN 400W X-Band GaN BUC (AC + EXT Ref)
The Standard Version MEDIAN BUCs offer higher gain to reduce the need for line amplifiers in long cable runs (IFL). In contrast, the WGS-Compatible Versions have lower gain to allow operation with IF signals driven up to 0 dBm.
Cyber-Hardened Intelligent BUCs are designed to enhance satellite ground terminal security for industries requiring optimized and flexible protection. These BUCs implement effective security management controls—including encrypted authentication, privacy, and access control—to ensure end-to-end message transmission. They help protect against session hijacking, password attacks, and eavesdropping.
KEY SPECIFICATIONS | |
Band | X-Band |
External Ref Freq | 10 mHz -12 to +5 dBm |
Frequency Sense | Non-Inverting |
Input Frequency Band 1 | 950 - 1450 MHz |
Number Of Onboard Los | Single-Band |
Output Frequency Band 1 | 7.900 - 8.400 GHz |
Output Power Rated | 400W |
Reference Type | External Reference |
RF SPECIFICATIONS | |
AM-PM Conversion | < 3.0 deg/dB @PLin |
Attenuator Range | 30 dB variable in 0.1 dB steps |
Gain Flatness (1Mhz) | 0.25 dB p-p max |
Gain Flatness (36Mhz) | 1.5 dB p-p max |
Gain Flatness (Over Full Band) | 4 dB p-p max |
Gain Variation Over Temperature (Open Loop) | 3 dB p-p max |
Gain Variation Over Temperature (Witg AGC) | 1 dB p-p max |
Gain Version | Std Options and Std Specs |
Harmonics | -60 dBc max. |
Input Impedance | 50 Ohm |
Input Power Detector Range | -55 to -20 dBm |
Input VSWR | 1.5 : 1 |
Level Stability With ALC | ± 0.5 dB |
Output Noise Power Density Rx | < -75 dBm/Hz (without Rx reject filter); < -166 dBm/Hz (with optional Rx reject filter) |
Output Noise Power Density Tx | < -75 dBm/Hz |
Output Plin | +53 dBm |
Output Psat | +56 dBm |
Output Spurious In Band | -65 dBc |
Output Spurious Out Of Band | Complies with MIL-STD 188-164C |
Output VSWR | 1.3 : 1 max |
Phase Noise 0.01Khz Offset Max | -115 dBC/Hz |
Phase Noise 0.1Khz Offset Max | -140 dBc/Hz |
Phase Noise 1Khz Offset Max | -150 dBc/Hz |
Phase Noise 10Khz Offset Max | -155 dBc/Hz |
Small Signal Gain | 82 dB min |
ELECTRICAL SPECIFICATIONS | |
Current Consumption Plin | 1800 VA |
Current Consumption Psat | 2200 VA |
Output Power Detector Range | Rated power to -20 dB |
Power Reading Accuracy | ± 1.0 dB max. |
Power Requirements | 200 to 240 VAC |
Power Supply | AC Powered |
INTERFACE SPECIFICATIONS | |
IF Connector | F |
Output Interface | CPR-112G |
M AND C SPECIFICATIONS | |
M And C Interface | Standard M&C |
Option | Standard M&C |
ENVIRONMENTAL SPECIFICATIONS | |
Altitude | 10,000 ft (3,000 m) ASL |
Humidity | 100% Condensing |
Temperature Operational | -40°C To +55°C |
PHYSICAL SPECIFICATIONS | |
Product Height Case 1 | 188 mm |
Product Length Case 1 | 610 mm |
Product Weight | 18 kg |
Product Width Case 1 | 254 mm |
ADDITIONAL INFORMATION | |
Aluminium Content | 0 Kg |
Aluminium Total Value | $ 0 |
Country Of Origin | Made in United States of America |
ECCN Number | EAR99 |
Ex Works | Richmond, BC, Canada |
Harmonized System Code | 8517620090 |
Package Height Case 1 | 381.0 mm |
Package Length Case 1 | 787.4 mm |
Package Width Case 1 | 381.0 mm |
Unit Package Weight | 22.23 kg |
Warranty | 3 years |
The Standard Version MEDIAN BUCs offer higher gain to reduce the need for line amplifiers in long cable runs (IFL). In contrast, the WGS-Compatible Versions have lower gain to allow operation with IF signals driven up to 0 dBm.
Cyber-Hardened Intelligent BUCs are designed to enhance satellite ground terminal security for industries requiring optimized and flexible protection. These BUCs implement effective security management controls—including encrypted authentication, privacy, and access control—to ensure end-to-end message transmission. They help protect against session hijacking, password attacks, and eavesdropping.
KEY SPECIFICATIONS | |
Band | X-Band |
External Ref Freq | 10 mHz -12 to +5 dBm |
Frequency Sense | Non-Inverting |
Input Frequency Band 1 | 950 - 1450 MHz |
Number Of Onboard Los | Single-Band |
Output Frequency Band 1 | 7.900 - 8.400 GHz |
Output Power Rated | 400W |
Reference Type | External Reference |
RF SPECIFICATIONS | |
AM-PM Conversion | < 3.0 deg/dB @PLin |
Attenuator Range | 30 dB variable in 0.1 dB steps |
Gain Flatness (1Mhz) | 0.25 dB p-p max |
Gain Flatness (36Mhz) | 1.5 dB p-p max |
Gain Flatness (Over Full Band) | 4 dB p-p max |
Gain Variation Over Temperature (Open Loop) | 3 dB p-p max |
Gain Variation Over Temperature (Witg AGC) | 1 dB p-p max |
Gain Version | Std Options and Std Specs |
Harmonics | -60 dBc max. |
Input Impedance | 50 Ohm |
Input Power Detector Range | -55 to -20 dBm |
Input VSWR | 1.5 : 1 |
Level Stability With ALC | ± 0.5 dB |
Output Noise Power Density Rx | < -75 dBm/Hz (without Rx reject filter); < -166 dBm/Hz (with optional Rx reject filter) |
Output Noise Power Density Tx | < -75 dBm/Hz |
Output Plin | +53 dBm |
Output Psat | +56 dBm |
Output Spurious In Band | -65 dBc |
Output Spurious Out Of Band | Complies with MIL-STD 188-164C |
Output VSWR | 1.3 : 1 max |
Phase Noise 0.01Khz Offset Max | -115 dBC/Hz |
Phase Noise 0.1Khz Offset Max | -140 dBc/Hz |
Phase Noise 1Khz Offset Max | -150 dBc/Hz |
Phase Noise 10Khz Offset Max | -155 dBc/Hz |
Small Signal Gain | 82 dB min |
ELECTRICAL SPECIFICATIONS | |
Current Consumption Plin | 1800 VA |
Current Consumption Psat | 2200 VA |
Output Power Detector Range | Rated power to -20 dB |
Power Reading Accuracy | ± 1.0 dB max. |
Power Requirements | 200 to 240 VAC |
Power Supply | AC Powered |
INTERFACE SPECIFICATIONS | |
IF Connector | F |
Output Interface | CPR-112G |
M AND C SPECIFICATIONS | |
M And C Interface | Standard M&C |
Option | Standard M&C |
ENVIRONMENTAL SPECIFICATIONS | |
Altitude | 10,000 ft (3,000 m) ASL |
Humidity | 100% Condensing |
Temperature Operational | -40°C To +55°C |
PHYSICAL SPECIFICATIONS | |
Product Height Case 1 | 188 mm |
Product Length Case 1 | 610 mm |
Product Weight | 18 kg |
Product Width Case 1 | 254 mm |
ADDITIONAL INFORMATION | |
Aluminium Content | 0 Kg |
Aluminium Total Value | $ 0 |
Country Of Origin | Made in United States of America |
ECCN Number | EAR99 |
Ex Works | Richmond, BC, Canada |
Harmonized System Code | 8517620090 |
Package Height Case 1 | 381.0 mm |
Package Length Case 1 | 787.4 mm |
Package Width Case 1 | 381.0 mm |
Unit Package Weight | 22.23 kg |
Warranty | 3 years |