Minature Signal Generator 25 MHz to 3000 MHz with USB or RS232 control interface adjustable in 1 Hz step sizes. Internal or External reference fitted with SMA Female RF connectors.
| RF Performance | |
| Frequency Range | 25 - 3000MHz |
| Frequency Step Size | 1Hz |
| Output Power Level | +13dBm |
| Output Range | +13dBm to -17dBm, 0.5dB Steps (output level set in dBm) |
| Internal Reference | 100MHz, +/-1ppm over temperature, +/-1ppm per year |
| Phase Noise Max (dBc/Hz) | 25 - 250MHz: -98 (1kHz), -96 (10kHz), -83 (100kHz) 250 - 1000MHz: -100 (1kHz), -98 (10kHz), -90 (100kHz) 1000 - 3000MHz: -112 (1kHz), -106 (10kHz), -101 (100kHz) |
| Spurious | Maximum: <-50dBc, Typical: <-70dBc |
| Harmonics | Maximum: -20dBc, Typical: -25dBc |
| RF Output Connector | SMA Female |
| Reference Connector | SMA Female Reference Input / Output autodetect and switch 100MHz Output Selectable 10 or 100MHz input (software programmable frequency) @ -4 to +12dBm |
| Power | |
| Power Input | 9 - 28V DC 12V, 3.0A AC adaptor with 1.20m lead included Current consumption: 300mA typ at 12V Can be powered also via USB3.0, current consumption: 860mA typ at 5V |
| Power Selection | Automatic Switching Coaxial Power jack selected by default USB power used when coaxial power not present USB power used when coaxial power not present |
| Interface | |
| Control Interface | USB: Virtual COM port RS-232: 9-pin male D-sub connector Ethernet: RJ45 connector |
| Output Modes | Continuous |
| Sweep | |
| External Trigger | Pin 4 of RS-232 connector: Pulse TTL/RS232 levels, 50ms min. pulse width |
| Manual trigger via GUI | |
| Status Indicators | Power Lock RF Output Reference Out Third-part terminal application (e.g. HyperTerm): ASCII commands Graphical User Interface Executable File: Adjust frequency and output power level Set reference frequency Select operation mode Set power-on defaults Adjust sweep configuration Change device network settings Control multiple units |
| Internal Memory | Non-volatile, automatically stores most recent settings |
| Environmental | |
| Operating Temperature | -20 to +50C |
| Storage Temperature | -40 to +85C |
| Mechanical | |
| Dimensions | 163mm x 103mm x 30.5mm |
| Weight | 350g |
5 customers are viewing this product
Details
Minature Signal Generator 25 MHz to 3000 MHz with USB or RS232 control interface adjustable in 1 Hz step sizes. Internal or External reference fitted with SMA Female RF connectors.
| RF Performance | |
| Frequency Range | 25 - 3000MHz |
| Frequency Step Size | 1Hz |
| Output Power Level | +13dBm |
| Output Range | +13dBm to -17dBm, 0.5dB Steps (output level set in dBm) |
| Internal Reference | 100MHz, +/-1ppm over temperature, +/-1ppm per year |
| Phase Noise Max (dBc/Hz) | 25 - 250MHz: -98 (1kHz), -96 (10kHz), -83 (100kHz) 250 - 1000MHz: -100 (1kHz), -98 (10kHz), -90 (100kHz) 1000 - 3000MHz: -112 (1kHz), -106 (10kHz), -101 (100kHz) |
| Spurious | Maximum: <-50dBc, Typical: <-70dBc |
| Harmonics | Maximum: -20dBc, Typical: -25dBc |
| RF Output Connector | SMA Female |
| Reference Connector | SMA Female Reference Input / Output autodetect and switch 100MHz Output Selectable 10 or 100MHz input (software programmable frequency) @ -4 to +12dBm |
| Power | |
| Power Input | 9 - 28V DC 12V, 3.0A AC adaptor with 1.20m lead included Current consumption: 300mA typ at 12V Can be powered also via USB3.0, current consumption: 860mA typ at 5V |
| Power Selection | Automatic Switching Coaxial Power jack selected by default USB power used when coaxial power not present USB power used when coaxial power not present |
| Interface | |
| Control Interface | USB: Virtual COM port RS-232: 9-pin male D-sub connector Ethernet: RJ45 connector |
| Output Modes | Continuous |
| Sweep | |
| External Trigger | Pin 4 of RS-232 connector: Pulse TTL/RS232 levels, 50ms min. pulse width |
| Manual trigger via GUI | |
| Status Indicators | Power Lock RF Output Reference Out Third-part terminal application (e.g. HyperTerm): ASCII commands Graphical User Interface Executable File: Adjust frequency and output power level Set reference frequency Select operation mode Set power-on defaults Adjust sweep configuration Change device network settings Control multiple units |
| Internal Memory | Non-volatile, automatically stores most recent settings |
| Environmental | |
| Operating Temperature | -20 to +50C |
| Storage Temperature | -40 to +85C |
| Mechanical | |
| Dimensions | 163mm x 103mm x 30.5mm |
| Weight | 350g |