ETL Systems
ETL Systems COM02L1P-2502 L-band Splitter 2-way - DC + 10MHz Pass
Request a quote at Contact@orbitalconnect.com or +1.888.218.9394
L-band Splitter / L-band Combiner - Passive 2-way with 10MHz and DC pass on both output ports.
Applications: Typical fields of applications are telecom infrastructures, satellite systems, microwave links, test and instrumentation and radar networks.
• All RF ports DC & 10MHz pass
Available with RF connector options:
• 50 Ω SMA
• 50 Ω N-type
• 50 Ω BNC
• 75 Ω BNC
• 75 Ω F-type
| RF Parameters | ||||||
| COM02L1P-2502-XXXX | S5S5 | N5N5 | B5B5 | B7B7 | F7F7 | |
| Frequency Range | 850 - 2150MHz | |||||
| RF Connectors | 50Ω SMA | 50Ω N-Type | 50Ω BNC | 75Ω BNC | 75Ω F-Type | |
| Mean Insertion Loss (dB) | 0.4 ± 0.2 | 0.4 ± 0.2 | 0.4 ± 0.2 | 0.4 ± 0.2 | 0.4 ± 0.2 | |
| Flatness ± (dB) | 0,25 | 0,25 | 0,25 | 0,25 | 0,25 | |
| Input Return Loss (dB) | Typ. Min | 20 | 20 | 20 | 20 | 20 |
| 16 | 16 | 16 | 16 | 16 | ||
| Output Return Loss (dB) | Typ. Min | 26 | 26 | 26 | 26 | 26 |
| 18 | 18 | 18 | 18 | 18 | ||
| Isolation (dB) | Typ. Min |
25 | 25 | 25 | 25 | 25 |
| 20 | 20 | 20 | 20 | 20 | ||
| Amplitude Balance (dB) | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.5 | ≤0.5 | |
| Phase Balance (Φ) | ≤2º | ≤2º | ≤2º | ≤5º | ≤5º | |
| The given Insertion Loss specified is the loss above the theoretical limit for a lossless divider 10MHz Insertion Loss is up to 3dB above the theoretical loss* 10MHz Rejection is 20dB* *To ports which are applicable |
||||||
| Max Operating Parameters | |
| Input RF Power into matched load with 20dB return loss | +37dBm (5W) as splitter +27dBm (500mW) as combiner |
| DC Voltage | 35V on any RF port |
| DC Current | 500mA |
| DC Consumption | N/A |
| Environmental | |
| Operating Temperature | 0˚C to +45˚C |
| Storage Temperature | -20˚C to +75˚C |
| Location | Indoor use Only |
| Humidity Max. | 85% non-condensing |
| Altitude Max. | 10,000 feet |
L-band Splitter / L-band Combiner - Passive 2-way with 10MHz and DC pass on both output ports.
Applications: Typical fields of applications are telecom infrastructures, satellite systems, microwave links, test and instrumentation and radar networks.
• All RF ports DC & 10MHz pass
Available with RF connector options:
• 50 Ω SMA
• 50 Ω N-type
• 50 Ω BNC
• 75 Ω BNC
• 75 Ω F-type
| RF Parameters | ||||||
| COM02L1P-2502-XXXX | S5S5 | N5N5 | B5B5 | B7B7 | F7F7 | |
| Frequency Range | 850 - 2150MHz | |||||
| RF Connectors | 50Ω SMA | 50Ω N-Type | 50Ω BNC | 75Ω BNC | 75Ω F-Type | |
| Mean Insertion Loss (dB) | 0.4 ± 0.2 | 0.4 ± 0.2 | 0.4 ± 0.2 | 0.4 ± 0.2 | 0.4 ± 0.2 | |
| Flatness ± (dB) | 0,25 | 0,25 | 0,25 | 0,25 | 0,25 | |
| Input Return Loss (dB) | Typ. Min | 20 | 20 | 20 | 20 | 20 |
| 16 | 16 | 16 | 16 | 16 | ||
| Output Return Loss (dB) | Typ. Min | 26 | 26 | 26 | 26 | 26 |
| 18 | 18 | 18 | 18 | 18 | ||
| Isolation (dB) | Typ. Min |
25 | 25 | 25 | 25 | 25 |
| 20 | 20 | 20 | 20 | 20 | ||
| Amplitude Balance (dB) | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.5 | ≤0.5 | |
| Phase Balance (Φ) | ≤2º | ≤2º | ≤2º | ≤5º | ≤5º | |
| The given Insertion Loss specified is the loss above the theoretical limit for a lossless divider 10MHz Insertion Loss is up to 3dB above the theoretical loss* 10MHz Rejection is 20dB* *To ports which are applicable |
||||||
| Max Operating Parameters | |
| Input RF Power into matched load with 20dB return loss | +37dBm (5W) as splitter +27dBm (500mW) as combiner |
| DC Voltage | 35V on any RF port |
| DC Current | 500mA |
| DC Consumption | N/A |
| Environmental | |
| Operating Temperature | 0˚C to +45˚C |
| Storage Temperature | -20˚C to +75˚C |
| Location | Indoor use Only |
| Humidity Max. | 85% non-condensing |
| Altitude Max. | 10,000 feet |
| Download Name | |
| L-BAND SPLITTER 2-WAY - DC + 10MHZ PASS Datasheet | |