Request a quote at Contact@orbitalconnect.com or +1.888.218.9394
Alto Broadband Attenuator Module with variable gain
The broadband hot swap variable attenuation module is designed to work in the Genus 1U chassis series, operating over 500 to 3000MHz. The module has - 5 to –55dB variable gain range, and the chassis has the capacity to house up to 16 amplifier modules. Other modules types are also available, these can be mixed and housed in the Genus chassis.
| Chassis Specification | |
| Dimensions/Weight/Colour | 1U high x 550mm deep x 19" wide / <10kg / RAL9003 - white (semi-matte) |
| Capacity | 17 module slots. Note: Actual modules may require >1 slot. Refer to required module spec table. |
| Temperature | Operating: 0˚C to +45˚C Storage: -20˚C to +75˚C |
| Location/Humidity/Altitude | Indoor use only / 20 to 90% non-condensing / 2,000m AMSL (Operational) 8,000m AMSL (Storage) Above Mean Sea Level |
| Control & Monitoring | Local: HMI, capacitive touch screen Remote: Ethernet via RJ45, 10BaseT/100 BaseTx. ETL TCP/IP, SNMPv2/3, HTTPS & built-in web server. HMI and CPU field replaceable. |
| MTTR | 20 minutes (15 minutes to retrieve spare part and 5 mins to replace). Applies to LRUs only and assumed in-house stock. |
| AC Input/Consumption | 85-264Vac 50/60Hz / 275W max. consumption at steady state |
| PSU Redundancy | Dual redundant and alarmed. Diode OR. Hot swappable. |
| Input & Output Ports | Dependant upon module fitted |
Alto Broadband Attenuator Module with variable gain
The broadband hot swap variable attenuation module is designed to work in the Genus 1U chassis series, operating over 500 to 3000MHz. The module has - 5 to –55dB variable gain range, and the chassis has the capacity to house up to 16 amplifier modules. Other modules types are also available, these can be mixed and housed in the Genus chassis.
| Chassis Specification | |
| Dimensions/Weight/Colour | 1U high x 550mm deep x 19" wide / <10kg / RAL9003 - white (semi-matte) |
| Capacity | 17 module slots. Note: Actual modules may require >1 slot. Refer to required module spec table. |
| Temperature | Operating: 0˚C to +45˚C Storage: -20˚C to +75˚C |
| Location/Humidity/Altitude | Indoor use only / 20 to 90% non-condensing / 2,000m AMSL (Operational) 8,000m AMSL (Storage) Above Mean Sea Level |
| Control & Monitoring | Local: HMI, capacitive touch screen Remote: Ethernet via RJ45, 10BaseT/100 BaseTx. ETL TCP/IP, SNMPv2/3, HTTPS & built-in web server. HMI and CPU field replaceable. |
| MTTR | 20 minutes (15 minutes to retrieve spare part and 5 mins to replace). Applies to LRUs only and assumed in-house stock. |
| AC Input/Consumption | 85-264Vac 50/60Hz / 275W max. consumption at steady state |
| PSU Redundancy | Dual redundant and alarmed. Diode OR. Hot swappable. |
| Input & Output Ports | Dependant upon module fitted |