Request a quote at Contact@orbitalconnect.com or +1.888.218.9394
Alto L-band Redundant Amplifier Module with low noise, high linearity, variable gain and slope control
The L-band redundant low noise amplifier module is designed to work in the Genus 1U redundant chassis range, operating over 850-2150 MHz. The module has low noise, high linearity, with variable gain and slope control.
| Chassis Specification | |
| Dimensions/Weight/Colour | 1U high x 550mm deep x 19" wide / <10kg / RAL9003 - white (semi-matte) |
| Capacity | 17 module slots. Note: Actual modules may require >1 slot. Refer to required module spec table. |
| Temperature | Operating: 0˚C to +45˚C |
| Storage: -20˚C to +75˚C | |
| Location/Humidity/Altitude | Indoor use only / 20 to 90% non-condensing / 2,000m AMSL (Operational) 8,000m AMSL (Storage) Above Mean Sea Level |
| Control & Monitoring | Local: HMI, capacitive touch screen |
| Remote: Ethernet via RJ45, 10BaseT/100 BaseTx. ETL TCP/IP, SNMPv2/3, HTTPS & built-in web server.HMI and CPU field replaceable.MTTR 20 minutes (15 minutes to retrieve spare part and 5 mins to replace). Applies to LRUs only and assumed in-house stock. | |
| AC Input/Consumption | 85-264Vac 50/60Hz / 275W max. consumption at steady state |
| PSU Redundancy | Dual redundant and alarmed. Diode OR. Hot swappable. |
| Input & Output Ports | Dependant upon module fitted |
Alto L-band Redundant Amplifier Module with low noise, high linearity, variable gain and slope control
The L-band redundant low noise amplifier module is designed to work in the Genus 1U redundant chassis range, operating over 850-2150 MHz. The module has low noise, high linearity, with variable gain and slope control.
| Chassis Specification | |
| Dimensions/Weight/Colour | 1U high x 550mm deep x 19" wide / <10kg / RAL9003 - white (semi-matte) |
| Capacity | 17 module slots. Note: Actual modules may require >1 slot. Refer to required module spec table. |
| Temperature | Operating: 0˚C to +45˚C |
| Storage: -20˚C to +75˚C | |
| Location/Humidity/Altitude | Indoor use only / 20 to 90% non-condensing / 2,000m AMSL (Operational) 8,000m AMSL (Storage) Above Mean Sea Level |
| Control & Monitoring | Local: HMI, capacitive touch screen |
| Remote: Ethernet via RJ45, 10BaseT/100 BaseTx. ETL TCP/IP, SNMPv2/3, HTTPS & built-in web server.HMI and CPU field replaceable.MTTR 20 minutes (15 minutes to retrieve spare part and 5 mins to replace). Applies to LRUs only and assumed in-house stock. | |
| AC Input/Consumption | 85-264Vac 50/60Hz / 275W max. consumption at steady state |
| PSU Redundancy | Dual redundant and alarmed. Diode OR. Hot swappable. |
| Input & Output Ports | Dependant upon module fitted |