Agilis
Agilis ALB1302E7-16B ALB130 Series Lite 16W Ext. Ku-Band Block-Up Converter
OVERVIEW
This small and lightweight BUC is ideal for SOTM applications and also benefits fixed and maritime applications.
Designed to be mounted on the feed horn, the BUC has “Best in Class” efficiency and “lowest power consumption”. The unit works on a wide range DC power supply of 38V to 60V. Innovative and efficient thermal design makes this BUC one of the smallest, robust, reliable and rugged enough to withstand outdoor conditions in the industry.
The unit can be configured to work in 1:1 redundant mode by adding on a simple redundancy option to the basic unit.
DETAILS
- Compact and lightweight
- Can be powered directly from: iDirect X7 modem
- Best in class efficiency with less power consumption.
- Available in both standard and extended Ku-Band
- Forward power detection facility
- Intuitive monitoring & control through RS232/RS485 & Ethernet (SNMP & HTTP)
- Auto ranging 18 to 60VDC Power Supply
- Automatic fault identification & alarm generation
- Wide operating temperature range -40ºC to +60ºC
- IP65 rated housing (weather proof construction)
- RoHS compliant
Quality Assurance
100% of all BUCs go through stringent quality checks in addition to well defined Electrical Stress Screening to ensure operation in harsh outdoor environments. The BUCs are also subjected to seal test for water ingress verification.
Reliability
Field proven under harsh environment conditions, Agilis ODUs can withstand temperature ranging from -40ºC to +60ºC with up to 100% humidity
Technical Specifications | |
Transmit Frequency | 13.75GHz-14.5GHz |
IF Frequency Range | 950MHz to 1700MHz |
L.O Frequency | 12.8GHz (Extended Ku-Band) |
Output Power (P1dB) | 42dBm (16W) |
Small Signal Gain | 68dB Min (12W/16W) |
Gain Flatness | ±2dB over the O/P frequency band, ±2dB over the operating temperature range |
Gain Control | 20dB in steps of 0.5dB |
O/P spurious | According to EN301428 |
Phase Noise @ Offset | |
1KHz 10KHz 100KHz |
-73dBc/Hz -83dBc/Hz -93dBc/Hz |
I/P VSWR | 1.5:1 |
O/P VSWR | 1.25:1 (with optional external isolator) |
Noise Power Density Tx BD | -70dBW/4KHz |
Noise Power Density Rx BD | -142dBW/4KHz |
DC Power | |
Prime Power | 48VDC (range 38 to 60VDC) via external MS connector, Optional 230VAC (range 96 to 264VAC) |
Power Consumption | 280W (Typical 46dBm) |
Interfaces | |
IF Input Interface | 500hms N-type Female |
Output Interface | WR 75G |
External Reference | |
Frequency | 10MHz |
Power | -5dBm to +5dBm |
Monitor | BUC temperature, Status alarm, RF output power, LED status indication |
Control | Attenuation, RF output mute |
Tx Redundancy | External RCU (optional for 1+1 redundancy system requirement) |
Environmental | |
Operating Temperature | -40°C to +60°C |
Humidity | Up to 100% |
Weather protection | Sealed to IP65 |
Mechanical | |
Size | 160L x 93W x 85H mm |
Weight | 1.2kg |
Color | White Powder Coat |
OVERVIEW
This small and lightweight BUC is ideal for SOTM applications and also benefits fixed and maritime applications.
Designed to be mounted on the feed horn, the BUC has “Best in Class” efficiency and “lowest power consumption”. The unit works on a wide range DC power supply of 38V to 60V. Innovative and efficient thermal design makes this BUC one of the smallest, robust, reliable and rugged enough to withstand outdoor conditions in the industry.
The unit can be configured to work in 1:1 redundant mode by adding on a simple redundancy option to the basic unit.
DETAILS
- Compact and lightweight
- Can be powered directly from: iDirect X7 modem
- Best in class efficiency with less power consumption.
- Available in both standard and extended Ku-Band
- Forward power detection facility
- Intuitive monitoring & control through RS232/RS485 & Ethernet (SNMP & HTTP)
- Auto ranging 18 to 60VDC Power Supply
- Automatic fault identification & alarm generation
- Wide operating temperature range -40ºC to +60ºC
- IP65 rated housing (weather proof construction)
- RoHS compliant
Quality Assurance
100% of all BUCs go through stringent quality checks in addition to well defined Electrical Stress Screening to ensure operation in harsh outdoor environments. The BUCs are also subjected to seal test for water ingress verification.
Reliability
Field proven under harsh environment conditions, Agilis ODUs can withstand temperature ranging from -40ºC to +60ºC with up to 100% humidity
Technical Specifications | |
Transmit Frequency | 13.75GHz-14.5GHz |
IF Frequency Range | 950MHz to 1700MHz |
L.O Frequency | 12.8GHz (Extended Ku-Band) |
Output Power (P1dB) | 42dBm (16W) |
Small Signal Gain | 68dB Min (12W/16W) |
Gain Flatness | ±2dB over the O/P frequency band, ±2dB over the operating temperature range |
Gain Control | 20dB in steps of 0.5dB |
O/P spurious | According to EN301428 |
Phase Noise @ Offset | |
1KHz 10KHz 100KHz |
-73dBc/Hz -83dBc/Hz -93dBc/Hz |
I/P VSWR | 1.5:1 |
O/P VSWR | 1.25:1 (with optional external isolator) |
Noise Power Density Tx BD | -70dBW/4KHz |
Noise Power Density Rx BD | -142dBW/4KHz |
DC Power | |
Prime Power | 48VDC (range 38 to 60VDC) via external MS connector, Optional 230VAC (range 96 to 264VAC) |
Power Consumption | 280W (Typical 46dBm) |
Interfaces | |
IF Input Interface | 500hms N-type Female |
Output Interface | WR 75G |
External Reference | |
Frequency | 10MHz |
Power | -5dBm to +5dBm |
Monitor | BUC temperature, Status alarm, RF output power, LED status indication |
Control | Attenuation, RF output mute |
Tx Redundancy | External RCU (optional for 1+1 redundancy system requirement) |
Environmental | |
Operating Temperature | -40°C to +60°C |
Humidity | Up to 100% |
Weather protection | Sealed to IP65 |
Mechanical | |
Size | 160L x 93W x 85H mm |
Weight | 1.2kg |
Color | White Powder Coat |