null Skip to main content
Zoom the image with the mouse

Agilis

Agilis ALB1292C7-25B-F ALB129 Series 25W Ku-Band VSAT Outdoor Block-Up Converter (BUC)

No reviews yet
Product Code: ALB1292C7-25B-F
Condition: New
Availability: Please Contact Us At Contact@Orbitalconnect.Com Or 888.315.9545.
Weight: 4.70 KGS
Width: 20.00 (cm)
Height: 13.00 (cm)
Depth: 21.00 (cm)
$12,615.38

Agilis ALB1290F7-25C ALB129 Series 25W Ku-Band VSAT Outdoor Block-Up Converter (BUC)

Summary

Agilis ALB129 Series Feed Mount 16W Ku-BUC is small and lightweight BUC suitable for mobile applications and satellite uplink applications. This small and lightweight BUC is ideal for SOTM applications while also offering benefits for fixed and maritime applications.Designed to be mounted on the feed horn, the BUC has “Best in Class” efficiency and “lowest power consumption”. The unit works ona wide range DC power supply of 38V to 60V. Innovative and efficient thermal design makes this BUC one of the smallest, robust, reliable and rugged enough to withstand outdoor conditions in the industry.The unit can be configured to work in 1:1 redundant mode by adding on a simple redundancy option to the basic unit.

Features
• Compact and lightweight
• Feed mountable
• Best in class efficiency with lesspower consumption
• Available in both standard and extended Ku-Band
• Forward power detection facility
• Intuitive monitoring & control through RS232/RS485  & Ethernet (SNMP & HTTP)
• Auto ranging 38 to 60VDC Power Supply
• Optional input AC Voltage
• Automatic fault identification & alarm generation
• Wide operating temperature range -40ºC to +60ºC
• IP65 rated housing (weather proof construction)
• RoHS compliant
Reliability
Field proven under harsh environment conditions, Agilis ODUs can withstand temperature ranging from -40ºC to +60ºC with up to 100% humidity.
Quality Assurance
100% of all BUCs go through stringent quality checks in addition to well defined Electrical Stress Screening to ensure operation in harsh outdoor environments. The BUCs are also subjected to seal test for water ingress verification.
RF Specifications

Transmit Frequency

14.0 – 14.5GHz

(EXT Ku)

IF Frequency Range

950 – 1450MHz

(EXT Ku)

L.O Frequency

13.05GHz

(EXT Ku)

Output Power

44dBm 

Small Signal Gain

68dB Min

Gain Flatness

±2dB over the O/P frequency band

Gain Variation

±2dB over the operating temperature range

Gain Control

20dB in steps of 0.5dB

Inter modulation

-25dBc @ Relative to combine power of twocarriers at 3dB total power backoff from Rated Output power

O/P spurious

According to EN301428

Phase Noise @ O  set

 

1KHz

10KHz

100KHz

-73dBc/Hz
-83dBc/Hz
-93dBc/Hz

I/P VSWR

2.0:1

O/P VSWR

1.25:1 (with optional external isolator)

Noise Power Density Tx BD

70dBW/4KHz

Rx BD

142dBW/4KHz
DC Power

Prime Power

48VDC (range 38 to 60VDC) via external MS connector

  Optional 230VAC (range 96 to 264VAC)
Power Consumption 177.6W (max for 16W/20W/25W )
Interfaces
IF Input Interface 75 Ohms F-type Female
Output Interface WR 75G
External Reference Requirement

Frequency

10MHz

Power

-5dBm to +5dBm

External reference phase

 

noise requirement @ frequency offset

 

1KHz

10KHz

100KHz

-135dBc/Hz

-145dBc/Hz

-155dBc/Hz

Monitor & Control
Monitor BUC temperature
Status alarm
RF output power
LED status indication
Control Attenuation
  RF output mute
Interface RS232/RS485 & Ethernet (SNMP & HTTP) via external MS connector
Tx Redundancy External RCU (optional for 1+1 redundancy system requirement
Environmental
Operating Temperature -40ºC to +60ºC
  Optional (-40ºC to +70ºC for 16W)
Humidity Up to 100% Weather protection sealed to IP65
Mechanical

Size

200L x 130W x 130H mm 

Weight

3.5kg / 7.5lbs

4.7kg / 10.36lbs (AC option)

Color

White Powder Coat

5 customers are viewing this product
  • Norton Secured
  • TRUSTe Verified
  • Authorized.net
  • Accredited Business
  • Verified by Visa
  • Mastercard SecureCode
Details

Agilis ALB1290F7-25C ALB129 Series 25W Ku-Band VSAT Outdoor Block-Up Converter (BUC)

Summary

Agilis ALB129 Series Feed Mount 16W Ku-BUC is small and lightweight BUC suitable for mobile applications and satellite uplink applications. This small and lightweight BUC is ideal for SOTM applications while also offering benefits for fixed and maritime applications.Designed to be mounted on the feed horn, the BUC has “Best in Class” efficiency and “lowest power consumption”. The unit works ona wide range DC power supply of 38V to 60V. Innovative and efficient thermal design makes this BUC one of the smallest, robust, reliable and rugged enough to withstand outdoor conditions in the industry.The unit can be configured to work in 1:1 redundant mode by adding on a simple redundancy option to the basic unit.

Features
• Compact and lightweight
• Feed mountable
• Best in class efficiency with lesspower consumption
• Available in both standard and extended Ku-Band
• Forward power detection facility
• Intuitive monitoring & control through RS232/RS485  & Ethernet (SNMP & HTTP)
• Auto ranging 38 to 60VDC Power Supply
• Optional input AC Voltage
• Automatic fault identification & alarm generation
• Wide operating temperature range -40ºC to +60ºC
• IP65 rated housing (weather proof construction)
• RoHS compliant
Reliability
Field proven under harsh environment conditions, Agilis ODUs can withstand temperature ranging from -40ºC to +60ºC with up to 100% humidity.
Quality Assurance
100% of all BUCs go through stringent quality checks in addition to well defined Electrical Stress Screening to ensure operation in harsh outdoor environments. The BUCs are also subjected to seal test for water ingress verification.
RF Specifications

Transmit Frequency

14.0 – 14.5GHz

(EXT Ku)

IF Frequency Range

950 – 1450MHz

(EXT Ku)

L.O Frequency

13.05GHz

(EXT Ku)

Output Power

44dBm 

Small Signal Gain

68dB Min

Gain Flatness

±2dB over the O/P frequency band

Gain Variation

±2dB over the operating temperature range

Gain Control

20dB in steps of 0.5dB

Inter modulation

-25dBc @ Relative to combine power of twocarriers at 3dB total power backoff from Rated Output power

O/P spurious

According to EN301428

Phase Noise @ O  set

 

1KHz

10KHz

100KHz

-73dBc/Hz
-83dBc/Hz
-93dBc/Hz

I/P VSWR

2.0:1

O/P VSWR

1.25:1 (with optional external isolator)

Noise Power Density Tx BD

70dBW/4KHz

Rx BD

142dBW/4KHz
DC Power

Prime Power

48VDC (range 38 to 60VDC) via external MS connector

  Optional 230VAC (range 96 to 264VAC)
Power Consumption 177.6W (max for 16W/20W/25W )
Interfaces
IF Input Interface 75 Ohms F-type Female
Output Interface WR 75G
External Reference Requirement

Frequency

10MHz

Power

-5dBm to +5dBm

External reference phase

 

noise requirement @ frequency offset

 

1KHz

10KHz

100KHz

-135dBc/Hz

-145dBc/Hz

-155dBc/Hz

Monitor & Control
Monitor BUC temperature
Status alarm
RF output power
LED status indication
Control Attenuation
  RF output mute
Interface RS232/RS485 & Ethernet (SNMP & HTTP) via external MS connector
Tx Redundancy External RCU (optional for 1+1 redundancy system requirement
Environmental
Operating Temperature -40ºC to +60ºC
  Optional (-40ºC to +70ºC for 16W)
Humidity Up to 100% Weather protection sealed to IP65
Mechanical

Size

200L x 130W x 130H mm 

Weight

3.5kg / 7.5lbs

4.7kg / 10.36lbs (AC option)

Color

White Powder Coat

0 Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Customer Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Flexible Shipping Terms

UPS, FedEx, DHL

Extended Warranty

Contact our agents

Loyalty Program

Additional savings on return customers

24/7 Technical Support

+1.844.636.3262