Agilis
Agilis ALB1290C7-40M ALB129 Series Compact 40W Std. Ku-Band Block-Up Converter
Agilis ALB129 Series Compact 40W Ku-Band Block-Up Converter
This small and lightweight BUC is ideal for SOTM applications while also offering benefits for fixed and maritime applications.
Designed to be mounted on the feed horn, the BUC has “Best in Class” efficiency and “lowest power consumption” with less than 330W. The unit works on a wide range DC power supply of 38V to 60V. Innovative and efficient thermal design makes this BUC on of the smallest, robust, reliable and rugged enough to withstand outdoor conditions in the industry. The unit can be configured to work in 1:1 redundant mode by adding on a simple redundancy option to the basic unit.
Features
• Compact and lightweight
• Feed mountable
• Available in both standard and extended Ku-Band
• Forward power detection facility
• Intuitive monitoring & control through RS232/485 & Ethernet (SNMP & HTTP)
• Auto ranging 38 to 60VDC Power Supply
• Optional input AC Voltage
• Automatic fault identification & alarm generation
• Wide operating temperature range -40ºC to +60ºC
• IP65 rated housing ( Weather proof Construction)
• RoHS compliant
Quality Assurance
100% of all BUCs go through stringent quality checks in addition to well defined Electrical Stress Screening to ensure operation in harsh outdoor environments. The BUCs are also subjected to seal test for water ingress verification.
Reliability
Field proven under harsh environment conditions, Agilis ODUs can withstand temperature ranging from -40ºC to +60ºC with up to 100% humidity.
Technical Specifications | |
Transmit Frequency | 14.00 – 14.50GHz |
IF Frequency Range | 950 – 1450MHz |
LO Frequency | 13.05GHz |
Output Power (Pisa) | 46dBm |
Spectral Re-growth | 30dBc @2dB below rated power (Pics) at 1.0 x symbol rate offset for OQPSK or QPSK |
Small Signal Gain | 74dB Min |
Gain Flatness | ±2dB over the O/P frequency band, ±2dB over the operating temperature range |
Gain Control | 20 dB in step of 0.5 dB |
O/P spurious | According to EN301428 |
Phase Noise @ Offset | |
1KHz 10KHz 100KHz |
-73dBc/Hz -83dBc/Hz -93dBc/Hz |
I/P VSWR | 1.5:1 |
O/P VSWR | 1.25:1 (with optional external isolator) |
Noise Power Density Tx BD | 70dBW/4KHz |
Noise Power Density Rx BD | 142dBW/4KHz |
DC Power | |
Prime Power | 48VDC (range 38 to 60VDC) via external MS connector, Optional 230VAC (range 96 to 264VAC) |
Power Consumption | 280W (Typical 46dBm) |
Interfaces | |
IF Input Interface | 500hms N-type Female |
Output Interface | WR 75G |
External Reference | |
Frequency | 10MHz |
Power | -5dBm to +5dBm |
Monitor | BUC temperature, Status alarm, RF output power, LED status indication |
Control | Attenuation, RF output mute |
Tx Redundancy | External RCU (optional for 1+1 redundancy system requirement) |
Environmental | |
Operating Temperature | -40°C to +60°C |
Humidity | Up to 100% |
Weather protection | Sealed to IP65 |
Mechanical | |
Dimensions | 200L x 130W x 130H mm, 200L x 130W x 235H mm (AC option) |
Weight | 3.7kg/8.14lbs, 6.0kg/13.22lbs (AC option) |
Colour | White Powder Coat |
Agilis ALB129 Series Compact 40W Ku-Band Block-Up Converter
This small and lightweight BUC is ideal for SOTM applications while also offering benefits for fixed and maritime applications.
Designed to be mounted on the feed horn, the BUC has “Best in Class” efficiency and “lowest power consumption” with less than 330W. The unit works on a wide range DC power supply of 38V to 60V. Innovative and efficient thermal design makes this BUC on of the smallest, robust, reliable and rugged enough to withstand outdoor conditions in the industry. The unit can be configured to work in 1:1 redundant mode by adding on a simple redundancy option to the basic unit.
Features
• Compact and lightweight
• Feed mountable
• Available in both standard and extended Ku-Band
• Forward power detection facility
• Intuitive monitoring & control through RS232/485 & Ethernet (SNMP & HTTP)
• Auto ranging 38 to 60VDC Power Supply
• Optional input AC Voltage
• Automatic fault identification & alarm generation
• Wide operating temperature range -40ºC to +60ºC
• IP65 rated housing ( Weather proof Construction)
• RoHS compliant
Quality Assurance
100% of all BUCs go through stringent quality checks in addition to well defined Electrical Stress Screening to ensure operation in harsh outdoor environments. The BUCs are also subjected to seal test for water ingress verification.
Reliability
Field proven under harsh environment conditions, Agilis ODUs can withstand temperature ranging from -40ºC to +60ºC with up to 100% humidity.
Technical Specifications | |
Transmit Frequency | 14.00 – 14.50GHz |
IF Frequency Range | 950 – 1450MHz |
LO Frequency | 13.05GHz |
Output Power (Pisa) | 46dBm |
Spectral Re-growth | 30dBc @2dB below rated power (Pics) at 1.0 x symbol rate offset for OQPSK or QPSK |
Small Signal Gain | 74dB Min |
Gain Flatness | ±2dB over the O/P frequency band, ±2dB over the operating temperature range |
Gain Control | 20 dB in step of 0.5 dB |
O/P spurious | According to EN301428 |
Phase Noise @ Offset | |
1KHz 10KHz 100KHz |
-73dBc/Hz -83dBc/Hz -93dBc/Hz |
I/P VSWR | 1.5:1 |
O/P VSWR | 1.25:1 (with optional external isolator) |
Noise Power Density Tx BD | 70dBW/4KHz |
Noise Power Density Rx BD | 142dBW/4KHz |
DC Power | |
Prime Power | 48VDC (range 38 to 60VDC) via external MS connector, Optional 230VAC (range 96 to 264VAC) |
Power Consumption | 280W (Typical 46dBm) |
Interfaces | |
IF Input Interface | 500hms N-type Female |
Output Interface | WR 75G |
External Reference | |
Frequency | 10MHz |
Power | -5dBm to +5dBm |
Monitor | BUC temperature, Status alarm, RF output power, LED status indication |
Control | Attenuation, RF output mute |
Tx Redundancy | External RCU (optional for 1+1 redundancy system requirement) |
Environmental | |
Operating Temperature | -40°C to +60°C |
Humidity | Up to 100% |
Weather protection | Sealed to IP65 |
Mechanical | |
Dimensions | 200L x 130W x 130H mm, 200L x 130W x 235H mm (AC option) |
Weight | 3.7kg/8.14lbs, 6.0kg/13.22lbs (AC option) |
Colour | White Powder Coat |