ETL Systems
ETL Systems Stingray900 Stand-alone Outdoor Broadband Receive Fibre Converter
Product Code:
SRY-RX-B2-926
Condition:
New
Availability:
YES
Weight:
5.00 KGS
Width:
16.50
(cm)
Height:
8.50
(cm)
Depth:
5.00
(cm)
Request a quote at Contact@orbitalconnect.com or +1.888.315.9545
Single channel Broadband (50 - 2450 MHz) RF over fibre (single mode, 1100 to 1650nm) receive unit in a compact IP65 rated waterproof housing.
The unit features:
- Input connectors for redundant hot swap external power supplies.
- LED indicators for module OK and power.
For use with ETL's Broadband StingRay transmit unit SRY-TX-B2-925.
Use with single power supply unitSRY-PS-12-915 or dual redundant power supply SRY-PS-12-916-xx1K.
Specification | Value | |
Capacity | One RF over FIbre Optical Receive Unit | |
Power Connector (Cable mount LEMO 1K series 2 pin) | 1K - LEMO FGL.1K.302.CLLK75Z | |
Input ports | 50Ω N-type, 75Ω F-type. | |
Fibre output connector | Senko IP-SC/APC | |
Frequency | 50MHz to 2450MHz | |
Connector & impedances | 50Ω N-type |
75Ω F-type |
Input Return Loss (dB) Typ. | 18 | 16 |
Input Return Loss (dB) Min | 12 | 12 |
Output Return Loss (dB) Typ. / Min. | NA | NA |
Gain flatness (dB) | ±2.0 | ±2.0 |
Gain flatness 50 to 200 MHz (dB) | ±2.0 | ±2.0 |
Gain flatness 200 to 850 (dB) | ±2.0 | ±2.0 |
Gain flatness 850 to 2450 (dB) | ±2.0 | ±2.0 |
Output AGC flatness | ±2.0 dB over full band | Tx Input -10 to -40 dBm | |
OIP3 (dBm) | Typical 17 dBm Worst Case 14 dBm |
Test condition: SRY-RX-B2-926 , 0 dB optical link loss, -22 dBm tones at 2150 and 2152 MHz |
|
CNR (in any 36MHz) (dB) | Typical -50 dB Worst Case -45 dB |
Test condition: SRY-RX-B2-926 , 0 dB optical link loss, -10 dBm RF i/p power, -10 dBm RF o/p total power. |
|
NF (dB) | Typical 12dB Worst Case 15dB |
Test condition: SRY-RX-B2-926 , 0 dB optical link loss, -50 dBm RF i/p power, -10 dBm o/p power |
|
Group Delay variation (ns) | 2 over full band 1 over any 36MHz. |
||
SFDR (dB/Hz2/3) | 105 typ., 100 min | Test condition: SRY-RX-B2-926 , 10 km fibre, -13 dBm tones at 2150 and 2152 MHz |
|
IMD3 (dBc) | -65 typ., -60 min. | Test condition: SRY-RX-B2-926 , 10 km fibre, -13 dBm tones at 2150 and 2152 MHz |
|
RF Output Signal Range, total power (dBm) |
-30 to -10 | o/p range available under all i/p conditions | |
Module input voltage (V DC) | 12 | Use with PSU SRY-12-916-xx1K | |
DC consumption (W) | 4 | Max | |
External PSU Redundancy | Dual redundant hot swap external units | Separate Unit | |
Local Monitoring | Full remote monitoring, PSU voltage, RF amp current, temperature, laser power, RF modulation power, laser optical power. Contact ETL if remote monitoring and control is required. |
RF output Power (Fixed Gain Disabled) | ||||
Switch Settings | 2 | 3 | 4 | Notes |
-31 dBm | 0 | 0 | 0 | 1 = Switch State ON 0 = Switch State OFF When fixed gain is enabled gain range is set based on users input setting. |
-28 dBm | 0 | 0 | 1 | |
-25 dBm | 0 | 1 | 0 | |
-22 dBm | 0 | 1 | 1 | |
-19 dBm | 1 | 0 | 0 | |
-16 dBm | 1 | 0 | 1 | |
-13 dBm | 1 | 1 | 0 | |
-10 dBm | 1 | 1 | 1 |
5 customers are viewing this product
Details
Single channel Broadband (50 - 2450 MHz) RF over fibre (single mode, 1100 to 1650nm) receive unit in a compact IP65 rated waterproof housing.
The unit features:
- Input connectors for redundant hot swap external power supplies.
- LED indicators for module OK and power.
For use with ETL's Broadband StingRay transmit unit SRY-TX-B2-925.
Use with single power supply unitSRY-PS-12-915 or dual redundant power supply SRY-PS-12-916-xx1K.
Specification | Value | |
Capacity | One RF over FIbre Optical Receive Unit | |
Power Connector (Cable mount LEMO 1K series 2 pin) | 1K - LEMO FGL.1K.302.CLLK75Z | |
Input ports | 50Ω N-type, 75Ω F-type. | |
Fibre output connector | Senko IP-SC/APC | |
Frequency | 50MHz to 2450MHz | |
Connector & impedances | 50Ω N-type |
75Ω F-type |
Input Return Loss (dB) Typ. | 18 | 16 |
Input Return Loss (dB) Min | 12 | 12 |
Output Return Loss (dB) Typ. / Min. | NA | NA |
Gain flatness (dB) | ±2.0 | ±2.0 |
Gain flatness 50 to 200 MHz (dB) | ±2.0 | ±2.0 |
Gain flatness 200 to 850 (dB) | ±2.0 | ±2.0 |
Gain flatness 850 to 2450 (dB) | ±2.0 | ±2.0 |
Output AGC flatness | ±2.0 dB over full band | Tx Input -10 to -40 dBm | |
OIP3 (dBm) | Typical 17 dBm Worst Case 14 dBm |
Test condition: SRY-RX-B2-926 , 0 dB optical link loss, -22 dBm tones at 2150 and 2152 MHz |
|
CNR (in any 36MHz) (dB) | Typical -50 dB Worst Case -45 dB |
Test condition: SRY-RX-B2-926 , 0 dB optical link loss, -10 dBm RF i/p power, -10 dBm RF o/p total power. |
|
NF (dB) | Typical 12dB Worst Case 15dB |
Test condition: SRY-RX-B2-926 , 0 dB optical link loss, -50 dBm RF i/p power, -10 dBm o/p power |
|
Group Delay variation (ns) | 2 over full band 1 over any 36MHz. |
||
SFDR (dB/Hz2/3) | 105 typ., 100 min | Test condition: SRY-RX-B2-926 , 10 km fibre, -13 dBm tones at 2150 and 2152 MHz |
|
IMD3 (dBc) | -65 typ., -60 min. | Test condition: SRY-RX-B2-926 , 10 km fibre, -13 dBm tones at 2150 and 2152 MHz |
|
RF Output Signal Range, total power (dBm) |
-30 to -10 | o/p range available under all i/p conditions | |
Module input voltage (V DC) | 12 | Use with PSU SRY-12-916-xx1K | |
DC consumption (W) | 4 | Max | |
External PSU Redundancy | Dual redundant hot swap external units | Separate Unit | |
Local Monitoring | Full remote monitoring, PSU voltage, RF amp current, temperature, laser power, RF modulation power, laser optical power. Contact ETL if remote monitoring and control is required. |
RF output Power (Fixed Gain Disabled) | ||||
Switch Settings | 2 | 3 | 4 | Notes |
-31 dBm | 0 | 0 | 0 | 1 = Switch State ON 0 = Switch State OFF When fixed gain is enabled gain range is set based on users input setting. |
-28 dBm | 0 | 0 | 1 | |
-25 dBm | 0 | 1 | 0 | |
-22 dBm | 0 | 1 | 1 | |
-19 dBm | 1 | 0 | 0 | |
-16 dBm | 1 | 0 | 1 | |
-13 dBm | 1 | 1 | 0 | |
-10 dBm | 1 | 1 | 1 |