Using technology developed for ModuMAX™ amplifiers, these rack-mount SSPAs offer output powers of up to 50 watts in C-, X-, and Ku-Band satellite uplink bands
The SSPAs incorporate a modular architecture that includes the RF modules, power supplies, logic, fans, and front panel assembly. The amplifiers are designed for reliable service in fixed and mobile applications.
FEATURES:
- 25, 35, or 50 W saturated output power
- Digital gain adjustment (20 dB range)
- Forward power monitoring
- Microprocessor based monitor and control
- Serial interface (RS-232/-422/-485) stadard
- 10 Base-T network interface (SNMP)
- Integral 1:1 redundancy control
- RF output sample port
APPLIC ATIONS:
- Single-thread SSPA
- Redundant systems (1:1, 1:2)
- Fixed installations
- Mobile terminals
- Commercial, Government, and Military systems
ACCESSORIES:
- RCP-2001 remote panel
Parameter | Notes | Specification |
Frequency Range | C-band, Standard (“D”) C-Band, Extended (“M”) X-Band, Standard (“B”) Ku-Band, Standard (“M”) Ku-Band, Extended (“O”) |
5.85 to 6.425 GHz 5.85 to 6.725 GHz 7.90 to 8.40 GHz 14.00 to 14.50 GHz 13.75 to 14.50 GHz |
Gain, at Maximum Setting | 70 dB min., 75 dB max. | |
Gain vs. Temperature | 0 to 50° C | ±0.75 max., ±0.5 typical |
Gain Adjustment Range | Digital | 20 dB min. in 0.1 dB steps |
Gain Flatness | ±0.75 dB over the full band; ±0.30 dB over any 40 MHz | |
Saturated Power Output | 50 W C-Band 25 W C-Band 50 W X-Band 25 W X-Band 35 W Ku-Band 25 W Ku-Band |
+47 dBm typ. (50 W) +44 dBm typ. (25 W) +47 dBm typ. (50 W) +44 dBm typ. (25 W) +45.5 dBm typ. (35 W) +44 dBm typ. (25 W) |
Power Output at 1dB compression (P1 dB) | 50 W C-Band 25 W C-Band 50 W X-Band 25 W X-Band 35 W Ku-Band 25 W Ku-Band |
+46.5 dBm min. (45 W) +43.5 dBm min. (22 W) +46.5 dBm min. (45 W) +43.5 dBm min. (22 W) +44.5 dBm min. (28 W) +43.0 dBm min. (20 W) |
Two Tone Intermodulation | -25 dBc max.,-30 dBc typical at 3 dB total backoff from 1dB compression point | |
Noise Figure | 8 dB typical at maximum gain | |
Residual Noise | C-Band, 5.85–6.425 GHz C-Band, 3.4–4.2 GHz X-Band, 7.25–8.40 GHz Ku-Band, 13.75–14.50 GHz Ku-Band, 10.7–12.75 GHz |
-70 dBW/4 kHz -150 dBW/4 kHz -70 dBW/4 kHz -70 dBW/4 kHz -120 dBW/4 kHz |
Group Delay | Linear Parabolic Ripple | 0.03 ns/MHz 0.003 ns/MHz2 1.0 ns peak to peak |
AM/PM Conversion | 2.5°/dB typical, 3.5°/dB at (P1 dB) | |
Second Harmonic | -60 dBc typical at (P1 dB) | |
Spurious | -70 dBc max. at (P1 dB), in band | |
VSWR | Input Output |
1.3:1 max, 1.2:1 typical 1.5:1 max, 1.3:1 typical |
Front Panel Sample Ports | Output | -40 dB typical |
Connectors | RF Input RF Output, C-Band RF Output, X-Band RF Output, Ku-Band Sample Port Serial I/O System Network Power |
Type N Female CPR137G Waveguide CPR112G Waveguide WR75G Waveguide Type N Female 9-pos D-sub Female, mate supplied 15-pos D-sub, Male RJ-45 Jack IEC-320 |
Power Requirements | Voltage Frequency Power factor corrected |
100 to 240 VAC 63 Hz max., 47 Hz min. .99 typical |
Power Consumption | 50 W C-Band 25 W C-Band 50 W X-Band 25 W X-Band 35 W Ku-Band 25 W Ku-Band |
275 W typical, 375 W max. (1) 225 W typical, 325 W max. (1) 325 W typical, 400 W max. (1) 250 W typical, 350 W max. (1) 300 W typical, 350 W max. (1) 275 W typical, 325 W max. (1) |
Cooling System | Forced Air | |
Operating Temperature Range | Ambient/Inlet air | 0°C to +50°C |
Altitude Derating | 10,000 ft (3000 m) max. | Derate 2°C per 1000 ft (300 m) |
Dimensions | See outline drawing | 3.5” H x 19” W x 22” D; 89 mm H x 483 mm W x 559 mm D |
(1) Cold start, at -40 °C and POUT in saturation. |
Using technology developed for ModuMAX™ amplifiers, these rack-mount SSPAs offer output powers of up to 50 watts in C-, X-, and Ku-Band satellite uplink bands
The SSPAs incorporate a modular architecture that includes the RF modules, power supplies, logic, fans, and front panel assembly. The amplifiers are designed for reliable service in fixed and mobile applications.
FEATURES:
- 25, 35, or 50 W saturated output power
- Digital gain adjustment (20 dB range)
- Forward power monitoring
- Microprocessor based monitor and control
- Serial interface (RS-232/-422/-485) stadard
- 10 Base-T network interface (SNMP)
- Integral 1:1 redundancy control
- RF output sample port
APPLIC ATIONS:
- Single-thread SSPA
- Redundant systems (1:1, 1:2)
- Fixed installations
- Mobile terminals
- Commercial, Government, and Military systems
ACCESSORIES:
- RCP-2001 remote panel
Parameter | Notes | Specification |
Frequency Range | C-band, Standard (“D”) C-Band, Extended (“M”) X-Band, Standard (“B”) Ku-Band, Standard (“M”) Ku-Band, Extended (“O”) |
5.85 to 6.425 GHz 5.85 to 6.725 GHz 7.90 to 8.40 GHz 14.00 to 14.50 GHz 13.75 to 14.50 GHz |
Gain, at Maximum Setting | 70 dB min., 75 dB max. | |
Gain vs. Temperature | 0 to 50° C | ±0.75 max., ±0.5 typical |
Gain Adjustment Range | Digital | 20 dB min. in 0.1 dB steps |
Gain Flatness | ±0.75 dB over the full band; ±0.30 dB over any 40 MHz | |
Saturated Power Output | 50 W C-Band 25 W C-Band 50 W X-Band 25 W X-Band 35 W Ku-Band 25 W Ku-Band |
+47 dBm typ. (50 W) +44 dBm typ. (25 W) +47 dBm typ. (50 W) +44 dBm typ. (25 W) +45.5 dBm typ. (35 W) +44 dBm typ. (25 W) |
Power Output at 1dB compression (P1 dB) | 50 W C-Band 25 W C-Band 50 W X-Band 25 W X-Band 35 W Ku-Band 25 W Ku-Band |
+46.5 dBm min. (45 W) +43.5 dBm min. (22 W) +46.5 dBm min. (45 W) +43.5 dBm min. (22 W) +44.5 dBm min. (28 W) +43.0 dBm min. (20 W) |
Two Tone Intermodulation | -25 dBc max.,-30 dBc typical at 3 dB total backoff from 1dB compression point | |
Noise Figure | 8 dB typical at maximum gain | |
Residual Noise | C-Band, 5.85–6.425 GHz C-Band, 3.4–4.2 GHz X-Band, 7.25–8.40 GHz Ku-Band, 13.75–14.50 GHz Ku-Band, 10.7–12.75 GHz |
-70 dBW/4 kHz -150 dBW/4 kHz -70 dBW/4 kHz -70 dBW/4 kHz -120 dBW/4 kHz |
Group Delay | Linear Parabolic Ripple | 0.03 ns/MHz 0.003 ns/MHz2 1.0 ns peak to peak |
AM/PM Conversion | 2.5°/dB typical, 3.5°/dB at (P1 dB) | |
Second Harmonic | -60 dBc typical at (P1 dB) | |
Spurious | -70 dBc max. at (P1 dB), in band | |
VSWR | Input Output |
1.3:1 max, 1.2:1 typical 1.5:1 max, 1.3:1 typical |
Front Panel Sample Ports | Output | -40 dB typical |
Connectors | RF Input RF Output, C-Band RF Output, X-Band RF Output, Ku-Band Sample Port Serial I/O System Network Power |
Type N Female CPR137G Waveguide CPR112G Waveguide WR75G Waveguide Type N Female 9-pos D-sub Female, mate supplied 15-pos D-sub, Male RJ-45 Jack IEC-320 |
Power Requirements | Voltage Frequency Power factor corrected |
100 to 240 VAC 63 Hz max., 47 Hz min. .99 typical |
Power Consumption | 50 W C-Band 25 W C-Band 50 W X-Band 25 W X-Band 35 W Ku-Band 25 W Ku-Band |
275 W typical, 375 W max. (1) 225 W typical, 325 W max. (1) 325 W typical, 400 W max. (1) 250 W typical, 350 W max. (1) 300 W typical, 350 W max. (1) 275 W typical, 325 W max. (1) |
Cooling System | Forced Air | |
Operating Temperature Range | Ambient/Inlet air | 0°C to +50°C |
Altitude Derating | 10,000 ft (3000 m) max. | Derate 2°C per 1000 ft (300 m) |
Dimensions | See outline drawing | 3.5” H x 19” W x 22” D; 89 mm H x 483 mm W x 559 mm D |
(1) Cold start, at -40 °C and POUT in saturation. |