Request a quote at Contact@orbitalconnect.com or +1.888.218.9394
| Unit of Sale | Per foot (1 ft) |
| Quantity | Length in feet — e.g. enter 100 for 100 ft |
| Part Number | LMR-400-LLPX |
| Environment | Outdoor |
| Jacket | FP |
| Overall Diameter (mm) | 9.398 |
| Overall Diameter (in) | 0.37 |
| Weight Kg/m | 0.1548 |
| Weight lb/ft | 0.104 |
| Operating Temp.°C (°F) | -40° to 125°C (-40° to 257°F) |
| Min. Bend Radius (mm) | 25.4 |
| Min. Bend Radius (in) | 1 |
| Bending Moment (Nm) | 0.68 |
| Bending Moment (ft-lb) | 0.5 |
| Max Frequency (GHz) | 8 |
| Impedance (ohms) | 50 |
| Performance Property | Units | US (metric) |
|---|---|---|
| Velocity of Propagation | % | 76 |
| Dielectric Constant | NA | 1.73 |
| Time Delay | nS/ft (nS/m) | 1.34 (4.40) |
| Impedance | ohms | 50 |
| Capacitance | pF/ft (pF/m) | 26.7 (87.6) |
| Inductance | uH/ft (uH/m) | 0.067 (0.22) |
| Shielding Effectiveness | dB | >90 |
| DC Resistance | ||
| Inner Conductor | ohms/1000ft (/km) | 1.8 (5.9) |
| Outer Conductor | ohms/1000ft (/km) | 1.65 (5.4) |
| Voltage Withstand | Volts DC | 2500 |
| Jacket Spark | Volts RMS | 8000 |
| Peak Power | kW | 16 |
| Performance Property | Units | US (metric) |
|---|---|---|
| Bend Radius: installation | in. (mm) | 1.00 (25.4) |
| Bend Radius: repeated | in. (mm) | 4.0 (101.6) |
| Weight | lb/ft (kg/m) | 0.104 (0.15) |
| Tensile Strength | lb (kg) | 120 (54.5) |
| Flat Plate Crush | lb/in. (kg/mm) | 185 (3.31) |
| Performance Property | °F | °C |
|---|---|---|
| Installation Temperature Range | -40/+257 | -40/+125 |
| Storage Temperature Range | -40/+257 | -40/+125 |
| Operating Temperature Range | -40/+257 | -40/+125 |
| Description | Material | In. (mm) |
|---|---|---|
| Inner Conductor | Solid BCCAI | 0.095 (2.41) |
| Dielectric | Low density PTFE | 0.285 (7.24) |
| Outer Conductor | Aluminum Tape | 0.291 (7.39) |
| Overall Braid | Tinned Copper | 0.320 (8.13) |
| Jacket | Red Fluoropolymer | 0.370 (9.40) |
| Frequency (MHz) | 30 | 50 | 150 | 220 | 450 | 900 | 1500 | 1800 | 2000 | 2500 | 3400 | 5800 | 8000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Attenuation dB/100 ft | 0.7 | 0.9 | 1.6 | 1.9 | 2.8 | 4.0 | 5.2 | 5.7 | 6.1 | 6.8 | 8.0 | 10.7 | 13.0 |
| Attenuation dB/100 m | 2.3 | 3.0 | 5.3 | 6.4 | 9.2 | 13.2 | 17.1 | 18.9 | 19.9 | 22.4 | 26.4 | 35.1 | 42.7 |
| Avg. Power kW | 6.2 | 4.8 | 208 | 2.3 | 1.6 | 1.1 | 0.84 | 0.78 | 0.73 | 0.65 | 0.57 | 0.41 | 0.34 |
| Connectors | TC-400-716M-RA-D, TC-400-716M-X, TC-400-BM-RA-D, TC-400-HNM-RA, TC-400-MUHF, TC-400-NF-X, TC-400-NMH-X, TC-400-NMC-2, TC-400-NMH-RA-D, TC-400-NMH-RA-SS, TC-400-NM-RP, TC-400-QNM-X, TC-400-SM-X, TC-400-SF-X, TC-400-TM-X, TC-400-TM-RA-D, TC-400-TM-RP, TC-400-TM-RP-RA-D, TC-400-4310M-X, TC-400-NMH-PL-X, EZ-400-NMH-PL-X, EZ-400-TF-PL-X, EZ-400-TM-PL-X, TC-400-NF-BH-X, TC-400-BM-X |
LMR®-400-LLPX® is a 50 Ohm coaxial cable designed for indoor use within return air handling plenums, such as dropped ceilings and raised floors. It features a highly fire-retardant, low-smoke jacket that meets stringent safety standards, making it ideal for installations requiring both performance and code compliance.
| Unit of Sale | Per foot (1 ft) |
| Quantity | Length in feet — e.g. enter 100 for 100 ft |
| Part Number | LMR-400-LLPX |
| Environment | Outdoor |
| Jacket | FP |
| Overall Diameter (mm) | 9.398 |
| Overall Diameter (in) | 0.37 |
| Weight Kg/m | 0.1548 |
| Weight lb/ft | 0.104 |
| Operating Temp.°C (°F) | -40° to 125°C (-40° to 257°F) |
| Min. Bend Radius (mm) | 25.4 |
| Min. Bend Radius (in) | 1 |
| Bending Moment (Nm) | 0.68 |
| Bending Moment (ft-lb) | 0.5 |
| Max Frequency (GHz) | 8 |
| Impedance (ohms) | 50 |
| Performance Property | Units | US (metric) |
|---|---|---|
| Velocity of Propagation | % | 76 |
| Dielectric Constant | NA | 1.73 |
| Time Delay | nS/ft (nS/m) | 1.34 (4.40) |
| Impedance | ohms | 50 |
| Capacitance | pF/ft (pF/m) | 26.7 (87.6) |
| Inductance | uH/ft (uH/m) | 0.067 (0.22) |
| Shielding Effectiveness | dB | >90 |
| DC Resistance | ||
| Inner Conductor | ohms/1000ft (/km) | 1.8 (5.9) |
| Outer Conductor | ohms/1000ft (/km) | 1.65 (5.4) |
| Voltage Withstand | Volts DC | 2500 |
| Jacket Spark | Volts RMS | 8000 |
| Peak Power | kW | 16 |
| Performance Property | Units | US (metric) |
|---|---|---|
| Bend Radius: installation | in. (mm) | 1.00 (25.4) |
| Bend Radius: repeated | in. (mm) | 4.0 (101.6) |
| Weight | lb/ft (kg/m) | 0.104 (0.15) |
| Tensile Strength | lb (kg) | 120 (54.5) |
| Flat Plate Crush | lb/in. (kg/mm) | 185 (3.31) |
| Performance Property | °F | °C |
|---|---|---|
| Installation Temperature Range | -40/+257 | -40/+125 |
| Storage Temperature Range | -40/+257 | -40/+125 |
| Operating Temperature Range | -40/+257 | -40/+125 |
| Description | Material | In. (mm) |
|---|---|---|
| Inner Conductor | Solid BCCAI | 0.095 (2.41) |
| Dielectric | Low density PTFE | 0.285 (7.24) |
| Outer Conductor | Aluminum Tape | 0.291 (7.39) |
| Overall Braid | Tinned Copper | 0.320 (8.13) |
| Jacket | Red Fluoropolymer | 0.370 (9.40) |
| Frequency (MHz) | 30 | 50 | 150 | 220 | 450 | 900 | 1500 | 1800 | 2000 | 2500 | 3400 | 5800 | 8000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Attenuation dB/100 ft | 0.7 | 0.9 | 1.6 | 1.9 | 2.8 | 4.0 | 5.2 | 5.7 | 6.1 | 6.8 | 8.0 | 10.7 | 13.0 |
| Attenuation dB/100 m | 2.3 | 3.0 | 5.3 | 6.4 | 9.2 | 13.2 | 17.1 | 18.9 | 19.9 | 22.4 | 26.4 | 35.1 | 42.7 |
| Avg. Power kW | 6.2 | 4.8 | 208 | 2.3 | 1.6 | 1.1 | 0.84 | 0.78 | 0.73 | 0.65 | 0.57 | 0.41 | 0.34 |
| Connectors | TC-400-716M-RA-D, TC-400-716M-X, TC-400-BM-RA-D, TC-400-HNM-RA, TC-400-MUHF, TC-400-NF-X, TC-400-NMH-X, TC-400-NMC-2, TC-400-NMH-RA-D, TC-400-NMH-RA-SS, TC-400-NM-RP, TC-400-QNM-X, TC-400-SM-X, TC-400-SF-X, TC-400-TM-X, TC-400-TM-RA-D, TC-400-TM-RP, TC-400-TM-RP-RA-D, TC-400-4310M-X, TC-400-NMH-PL-X, EZ-400-NMH-PL-X, EZ-400-TF-PL-X, EZ-400-TM-PL-X, TC-400-NF-BH-X, TC-400-BM-X |
LMR®-400-LLPX® is a 50 Ohm coaxial cable designed for indoor use within return air handling plenums, such as dropped ceilings and raised floors. It features a highly fire-retardant, low-smoke jacket that meets stringent safety standards, making it ideal for installations requiring both performance and code compliance.