Times Microwave Systems
Times Microwave Systems LMR-600 Coaxial Cable, 50 Ohm, per Foot
Request a quote at Contact@orbitalconnect.com or +1.888.218.9394
Ordering Information
| Unit of Sale | Per foot (1 ft) |
| Quantity | Length in feet — e.g. enter 100 for 100 ft |
Key Specifications
| Part Number | LMR-600 |
| Environment | Outdoor |
| Jacket | PE |
| Overall Diameter (mm) | 14.986 |
| Overall Diameter (in) | 0.59 |
| Weight Kg/m | 0.1949 |
| Weight lb/ft | 0.131 |
| Operating Temp.°C (°F) | -40° to 85°C (-40° to 185°F) |
| Min. Bend Radius (mm) | 38.1 |
| Min. Bend Radius (in) | 1.5 |
| Bending Moment (Nm) | 3.73 |
| Bending Moment (ft-lb) | 2.75 |
| Max Frequency (GHz) | 8 |
| Impedance (ohms) | 50 |
| Stock Code | 54003 |
Electrical Specifications
| Performance Property | Units | US (metric) |
|---|---|---|
| Velocity of Propagation | % | 85 |
| Dielectric Constant | NA | 1.32 |
| Time Delay | nS/ft (nS/m) | 1.17 (3.83) |
| Impedance | ohms | 50 |
| Capacitance | pF/ft (pF/m) | 23.4 (76.6) |
| Inductance | uH/ft (uH/m) | 0.058 (0.19) |
| Shielding Effectiveness | dB | >90 |
| DC Resistance | ||
| Inner Conductor | ohms/1000ft (/km) | 0.53 (1.7) |
| Outer Conductor | ohms/1000ft (/km) | 1.2 (3.9) |
| Voltage Withstand | Volts DC | 4000 |
| Jacket Spark | Volts RMS | 8000 |
| Peak Power | kW | 40 |
Mechanical Specifications
| Performance Property | Units | US (metric) |
|---|---|---|
| Bend Radius: installation | in. (mm) | 1.50 (38.1) |
| Bend Radius: repeated | in. (mm) | 6.0 (152.4) |
| Bending Moment | ft-lb (N-m) | 2.75 (3.73) |
| Weight | lb/ft (kg/m) | 0.131 (0.20) |
| Tensile Strength | lb (kg) | 350 (158.9) |
| Flat Plate Crush | lb/in. (kg/mm) | 60 (1.07) |
Environmental Specifications
| Performance Property | °F | °C |
|---|---|---|
| Installation Temperature Range | -40/+185 | -40/+85 |
| Storage Temperature Range | -94/+185 | -70/+85 |
| Operating Temperature Range | -40/+185 | -40/+85 |
Construction Specifications
| Description | Material | In. (mm) |
|---|---|---|
| Inner Conductor | Solid BCCAl | 0.176 (4.47) |
| Dielectric | Foam PE | 0.455 (11.56) |
| Outer Conductor | Aluminum Tape | 0.461 (11.71) |
| Overall Braid | Tinned Copper | 0.490 (12.45) |
| Jacket | (see table) | 0.590 (14.99) |
Attenuation vs. Frequency (typical)
| Frequency (MHz) | 30 | 50 | 150 | 220 | 450 | 900 | 1500 | 1800 | 2000 | 2500 | 5800 | 8000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Attenuation dB/100 ft | 0.4 | 0.5 | 1.0 | 1.2 | 1.7 | 2.5 | 3.3 | 3.7 | 3.9 | 4.4 | 7.3 | 8.8 |
| Attenuation dB/100 m | 1.4 | 1.8 | 3.2 | 3.9 | 5.6 | 8.2 | 10.9 | 12.1 | 12.8 | 14.5 | 23.8 | 29.0 |
| Avg. Power kW | 5.51 | 4.24 | 2.41 | 1.97 | 1.35 | 0.93 | 0.70 | 0.63 | 0.59 | 0.52 | 0.32 | 0.26 |
Compatible Connectors
| Connectors | TC-600-716M-X, TC-600-BM-RA-D, TC-600-HNMC, TC-600-NF-X, TC-600-NF-BH, TC-600-NMC-2-D, TC-600-NMH-X, TC-600-NMH-RA-D, TC-600-TF-X, TC-600-TF-RP, TC-600-TM-RP, TC-600-TM-RA-D, EZ-600-4310M-X, EZ-600-4310M-RA-X, EZ-600-716F-X, EZ-600-716M-X, EZ-600-716M-RA-X, EZ-600-NF-BH-X, EZ-600-NF-X, EZ-600-NMH-X, EZ-600-NMC-2-D, EZ-600-NMK, EZ-600-QNF-X, EZ-600-QNM-X, EZ-600-QNM-RA-X, EZ-600-TF-X, EZ-600-TF-BH-X, EZ-600-TM-X, EZ-600-TM-RP, EZ-600-UM-X, EZ-600-NMH-RA-X, EZ-600-78-EIA |
Overview
The LMR®-600 coaxial cable is a high-performance, low-loss RF cable designed for use in applications where a flexible and durable cable with excellent electrical characteristics is required. With a 50 Ohm impedance and a UV-resistant jacket, this cable is well-suited for use in antenna feeder jumper assemblies and other RF transmission systems that require a high level of signal fidelity and minimal signal loss. Its unique design helps to reduce signal attenuation over long cable runs, making it ideal for applications that require extended cable lengths.
Ordering Information
| Unit of Sale | Per foot (1 ft) |
| Quantity | Length in feet — e.g. enter 100 for 100 ft |
Key Specifications
| Part Number | LMR-600 |
| Environment | Outdoor |
| Jacket | PE |
| Overall Diameter (mm) | 14.986 |
| Overall Diameter (in) | 0.59 |
| Weight Kg/m | 0.1949 |
| Weight lb/ft | 0.131 |
| Operating Temp.°C (°F) | -40° to 85°C (-40° to 185°F) |
| Min. Bend Radius (mm) | 38.1 |
| Min. Bend Radius (in) | 1.5 |
| Bending Moment (Nm) | 3.73 |
| Bending Moment (ft-lb) | 2.75 |
| Max Frequency (GHz) | 8 |
| Impedance (ohms) | 50 |
| Stock Code | 54003 |
Electrical Specifications
| Performance Property | Units | US (metric) |
|---|---|---|
| Velocity of Propagation | % | 85 |
| Dielectric Constant | NA | 1.32 |
| Time Delay | nS/ft (nS/m) | 1.17 (3.83) |
| Impedance | ohms | 50 |
| Capacitance | pF/ft (pF/m) | 23.4 (76.6) |
| Inductance | uH/ft (uH/m) | 0.058 (0.19) |
| Shielding Effectiveness | dB | >90 |
| DC Resistance | ||
| Inner Conductor | ohms/1000ft (/km) | 0.53 (1.7) |
| Outer Conductor | ohms/1000ft (/km) | 1.2 (3.9) |
| Voltage Withstand | Volts DC | 4000 |
| Jacket Spark | Volts RMS | 8000 |
| Peak Power | kW | 40 |
Mechanical Specifications
| Performance Property | Units | US (metric) |
|---|---|---|
| Bend Radius: installation | in. (mm) | 1.50 (38.1) |
| Bend Radius: repeated | in. (mm) | 6.0 (152.4) |
| Bending Moment | ft-lb (N-m) | 2.75 (3.73) |
| Weight | lb/ft (kg/m) | 0.131 (0.20) |
| Tensile Strength | lb (kg) | 350 (158.9) |
| Flat Plate Crush | lb/in. (kg/mm) | 60 (1.07) |
Environmental Specifications
| Performance Property | °F | °C |
|---|---|---|
| Installation Temperature Range | -40/+185 | -40/+85 |
| Storage Temperature Range | -94/+185 | -70/+85 |
| Operating Temperature Range | -40/+185 | -40/+85 |
Construction Specifications
| Description | Material | In. (mm) |
|---|---|---|
| Inner Conductor | Solid BCCAl | 0.176 (4.47) |
| Dielectric | Foam PE | 0.455 (11.56) |
| Outer Conductor | Aluminum Tape | 0.461 (11.71) |
| Overall Braid | Tinned Copper | 0.490 (12.45) |
| Jacket | (see table) | 0.590 (14.99) |
Attenuation vs. Frequency (typical)
| Frequency (MHz) | 30 | 50 | 150 | 220 | 450 | 900 | 1500 | 1800 | 2000 | 2500 | 5800 | 8000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Attenuation dB/100 ft | 0.4 | 0.5 | 1.0 | 1.2 | 1.7 | 2.5 | 3.3 | 3.7 | 3.9 | 4.4 | 7.3 | 8.8 |
| Attenuation dB/100 m | 1.4 | 1.8 | 3.2 | 3.9 | 5.6 | 8.2 | 10.9 | 12.1 | 12.8 | 14.5 | 23.8 | 29.0 |
| Avg. Power kW | 5.51 | 4.24 | 2.41 | 1.97 | 1.35 | 0.93 | 0.70 | 0.63 | 0.59 | 0.52 | 0.32 | 0.26 |
Compatible Connectors
| Connectors | TC-600-716M-X, TC-600-BM-RA-D, TC-600-HNMC, TC-600-NF-X, TC-600-NF-BH, TC-600-NMC-2-D, TC-600-NMH-X, TC-600-NMH-RA-D, TC-600-TF-X, TC-600-TF-RP, TC-600-TM-RP, TC-600-TM-RA-D, EZ-600-4310M-X, EZ-600-4310M-RA-X, EZ-600-716F-X, EZ-600-716M-X, EZ-600-716M-RA-X, EZ-600-NF-BH-X, EZ-600-NF-X, EZ-600-NMH-X, EZ-600-NMC-2-D, EZ-600-NMK, EZ-600-QNF-X, EZ-600-QNM-X, EZ-600-QNM-RA-X, EZ-600-TF-X, EZ-600-TF-BH-X, EZ-600-TM-X, EZ-600-TM-RP, EZ-600-UM-X, EZ-600-NMH-RA-X, EZ-600-78-EIA |
Overview
The LMR®-600 coaxial cable is a high-performance, low-loss RF cable designed for use in applications where a flexible and durable cable with excellent electrical characteristics is required. With a 50 Ohm impedance and a UV-resistant jacket, this cable is well-suited for use in antenna feeder jumper assemblies and other RF transmission systems that require a high level of signal fidelity and minimal signal loss. Its unique design helps to reduce signal attenuation over long cable runs, making it ideal for applications that require extended cable lengths.