ETL Systems
ETL Systems ALT-G2S-K4-146-K5K5 Alto Ka-Band Amplifier Module
Request a quote at Contact@orbitalconnect.com or +1.888.218.9394
Alto Ka-Band Amplifier Module fixed gain with low noise
Ka-band amplifier module operating over 27.0 to 31.0 GHz, with fixed gain and a low noise figure. The module is hot-swappable and designed to be housed in the Genus 2U 19" chassis. The Genus chassis has the capacity to hold up to 16 mixed RF modules (dependant upon configuration and type fitted). Please enquire for other available module types.
| Chassis Specification | |
| Dimensions/Weight/Colour | 2U high x 550mm deep x 19" wide / <10kg / RAL9003 - white (semi-matte) |
| Capacity | 17 module slots. Note: Actual modules may require >1 slot. Refer to required module spec table. |
| Temperature | Operating: 0˚C to +45˚C Storage: -20˚C to +75˚C |
| Location/Humidity/Altitude | Indoor use only / 20 to 90% non-condensing / 2,000m AMSL (Operational) 8,000m AMSL (Storage) Above Mean Sea Level |
| Control & Monitoring | Local: HMI, capacitive touch screen Remote: Ethernet via RJ45, 10BaseT/100 BaseTx. ETL TCP/IP, SNMPv2/3, HTTPS & built-in web server. HMI and CPU field replaceable. |
| MTTR | 20 minutes (15 minutes to retrieve spare part and 5 mins to replace). Applies to LRUs only and assumed in-house stock. |
| AC Input/Consumption | 85-264Vac 50/60Hz / 275W max. consumption at steady state |
| PSU Redundancy | Dual redundant and alarmed. Diode OR. Hot swappable. |
| Input & Output Ports | Dependant upon module fitted |
Alto Ka-Band Amplifier Module fixed gain with low noise
Ka-band amplifier module operating over 27.0 to 31.0 GHz, with fixed gain and a low noise figure. The module is hot-swappable and designed to be housed in the Genus 2U 19" chassis. The Genus chassis has the capacity to hold up to 16 mixed RF modules (dependant upon configuration and type fitted). Please enquire for other available module types.
| Chassis Specification | |
| Dimensions/Weight/Colour | 2U high x 550mm deep x 19" wide / <10kg / RAL9003 - white (semi-matte) |
| Capacity | 17 module slots. Note: Actual modules may require >1 slot. Refer to required module spec table. |
| Temperature | Operating: 0˚C to +45˚C Storage: -20˚C to +75˚C |
| Location/Humidity/Altitude | Indoor use only / 20 to 90% non-condensing / 2,000m AMSL (Operational) 8,000m AMSL (Storage) Above Mean Sea Level |
| Control & Monitoring | Local: HMI, capacitive touch screen Remote: Ethernet via RJ45, 10BaseT/100 BaseTx. ETL TCP/IP, SNMPv2/3, HTTPS & built-in web server. HMI and CPU field replaceable. |
| MTTR | 20 minutes (15 minutes to retrieve spare part and 5 mins to replace). Applies to LRUs only and assumed in-house stock. |
| AC Input/Consumption | 85-264Vac 50/60Hz / 275W max. consumption at steady state |
| PSU Redundancy | Dual redundant and alarmed. Diode OR. Hot swappable. |
| Input & Output Ports | Dependant upon module fitted |