null Skip to main content
Zoom the image with the mouse

Nisshinbo

Nisshinbo NJT5762KNA C-band 10W BUC 5.85 - 6.425 GHz

No reviews yet
Product Code: NJT5762KNA
Condition: New
Availability: YES
Weight: 3.20 KGS
Width: 21.95 (cm)
Height: 9.90 (cm)
Depth: 17.50 (cm)

Request a quote at Contact@orbitalconnect.com or +1.888.315.9545

About the BUC

The NJT5762KNA is a Nisshinbo block up converter (BUC) operating in C-Band, with an output range of 5.85 - 6.425 GHz and an N-type IF interface. Full electrical, mechanical and environmental specifications are listed below.

Key Specifications

BandC-Band
Output FrequencyC-Band: 5.85 - 6.425 GHz
IF ConnectorN-Connector
M&C OptionFSK Communications M&C Option, only for NJT5762 series
DC Power Input ConnectorIF Interface Connector
Power Supply, Operating VoltageAC Power Operation Option, 100 to 240 V AC

Electrical Specifications

Output RF Frequency Range5.85 to 6.425 GHz
Input IF Frequency Range950 to 1,525 MHz
Maximum IF Input Level(without damage)+13 dBm max.
Conversion TypeSingle, fixed L.O.
L.O. Frequency4.9 GHz
Frequency SensePositive
Output Power @ 1dB G.C.P. (P1dB)+40 dBm min. over temperature
IM3@ total power <= +40 dBm - 3 dB
-28 dBc typ., -26 dBc max.
Linear Gain64 dB nom., 58 dB min.
Gain Variation over frequency @ fixed temperature4 dBp-p max. over 575 MHz
2 dBp-p max. over 54 MHz
Gain Stability over temperature @ fixed frequency4 dBp-p max.
2 dBp-p typ.
Requirement for External ReferenceFrequency: 10 MHz (sine-wave)
Input Power: -5 to +5 dBm @ Input port
Phase Noise: -120 dBc/Hz max. @ 100 Hz
-130 dBc/Hz max. @ 1 kHz
-140 dBc/Hz max. @ 10 kHz
L.O. Phase Noise-60 dBc/Hz max. @ 100 Hz
-70 dBc/Hz max. @ 1 kHz
-80 dBc/Hz max. @ 10 kHz
-90 dBc/Hz max. @ 100 kHz
-100 dBc/Hz max. @ 1MHz
Spurious @ Pout = +40 dBmIn-band: -50 dBc max. @ 5.85 to 6.425 GHz
Receive-band: -70 dBm max. @ 3.625 to 4.2 GHz
Out-of-band: -50 dBc max.
Receive Band Noise Density-87 dBm/4kHz max. @ 3.625 to 4.2 GHz
Input Impedance50 ohms nom
Input V.S.W.R.2 : 1 max.
Output V.S.W.R.2 : 1 max.
Output Load V.S.W.R.Recommendation: 1.3 : 1 max.
Non Damage: Infinite : 1
DC Power RequirementVoltage Range: 100 to 240 VAC
*Details are mentioned on Appendix of “Indoor
150W AC/DC Power Supply Unit”.
MuteShut off the HPA in case of L.O. unlocked or no 10
MHz reference signal.
Shut off the HPA in case of L.O. unlocked or no 10 MHz
reference signal (or status of over temperature)
LED IndicatorGREEN: LO locked
RED: LO unlocked
(or no 10 MHz reference signal)
Monitor and ControlInterface: 650kHz FSK Signal on IF Connector
Functions: Monitor:
Tx Output Power / Temperature / Tx Status
/ Alarm (Over temperature
/ L.O. unlock)
Control:
Transmit On/Off
Performance: Tx Output Power:
Detector Range: 15 dB (up to P1dB)
Reading Accuracy: +/- 1.0 dB
*Details are mentioned on Appendix of
“Specifications of Monitor & Control”.
dBc at the IDU and IF signal
ircular
connector models to avoid
temperature which turn out at internal temperatur e of around 120 °C, and the Mute and
Alarm will function at status of over temperature. After the Mute and Alarm of over

Mechanical Specifications

Input InterfaceIF Connector: IF / Ref. / FSK M&C Signal / DC Power Input:
Coaxial Connector, N-type Female - 50 ohms
Output InterfaceWaveguide, CPR-137G (with Groove)
Dimension & Housing219.5 (L) x 175 (W) x 99 (H) mm
[8.64” (L) x 6.89” (W) x 3.90” (H)]
Weight3.2 kg typ.
[7.0 lbs typ.]
CoolingConvection Air Cooling
avoid

Environmental Specifications

Temperature Range (Ambient)Operating: -40 to +55 °C
Storage: -40 to +75 °C
Humidity0 to 100 % RH
Altitude15,000 feet (4,572 m)
Vibration (Survival)5 G [49.03 m/s2] (3 axis, 50 Hz to 2 kHz)
1 mm p-p (3 axis, 5 to 50 Hz)
Shock (Survival)30 G [294.20 m/s2] (3 axis)
Waterproof / Dustproof (IP Code Rating)IP 67
RegulationsEU Directive (CE Marking)
EMC - 2014/30/EU
RoHS - 2011/65/EU + (EU)2015/863
Safety: EN60950-1, EN60950-22
MTBF (by Method of Parts Count Reliability as Design Condition Prediction)120,000 hours and more at +55 °C

Power Supply Unit(PSU) - Electrical Specifications

Input AC Voltage RangeRated Range: 100 to 240 VAC
Absolute Maximum Rating: 90 to 264 VAC
Input AC Frequency Range50/60 Hz
Maximum Input AC Apparent Power200 VA
Output Voltage+48 VDC
Output Voltage Accuracy+/- 10 %
Output Current Range0 to 3.2 A
Maximum Output Power150W
Standby Mode Power10 W max.
Condition: No Connect BUC · No Output DC Power
Efficiency80 % typ. at 120 VAC, full load
Power Factor0.98 typ. at 120 VAC, full load
Output ON/OFF Controla) Rocker Switch on the Front Panel
b) Mode of DC Power Output
Option 1: To keep supplying
Option 2: Synchronization with input
DC voltage on/off
IF Frequency Range950 to 1,700 MHz
IF Input/ Output Impedance50 ohms nom
IF Input/ Output VSWR2 : 1 max.
IF Insertion Loss1.5 dB max.
Input DC Voltage Range+24 / +48 VDC
In case of option 2 in mode of DC power output,
50mA min. is needed from modem.
ProtectionInternal Primary Current Fuse
Short Protection
LED IndicatorDC Output (Power): GREEN: Supply a DC Power to BUC
Fan Alarm: GREEN: Normal Condition
RED: Abnormal Condition
and Fan must be Replaced

Power Supply Unit(PSU) - Mechanical Specifications

AC Input InterfaceIEC320-C14 Inlet
IF Input Interface ConnectorN-type Female Connector, 50 ohms
IF Output Interface ConnectorN-type Female Connector, 50 ohms
CoolingForced-air-cooled by Fan
Dimension & Housing290 (W) x 200 (D) x 44 (H) mm
[11.42” (W) x 7.87” (D) x 1.73” (H) ]
Weight1.6 kg
[3.5 lbs]

Power Supply Unit(PSU) - Environmental Specifications

Temperature Range (Ambient)Operating: 0 to +50 °C
Storage: -30 to +85 °C
HumidityOperating: 30 to 90 %Rh non-condensing
Storage: 10 to 95 %Rh
Vibration (Survival)Non Operation
2 G [19.6 m/s2] Constant
(10 to 55 Hz, Sweep Time: 1 min., 3 axis, 1 hour)
Shock (Survival)20 G [196.1 m/s2]
(3 axis)
RegulationsEU Directive (CE Marking)
EMC - 2014/30/EU
Low Voltage - 2014/35/EU
RoHS - 2011/65/EU, (EU)2015/863
UL Citification
Compliance StandardEN 55022
EN 55024
EN 61000-3-2/3
EN 60950-1 / UL60950-1
EN 62311
MTBF150,000 hours and more at +50 °C
as Design Condition
5 customers are viewing this product
  • Norton Secured
  • TRUSTe Verified
  • Authorized.net
  • Accredited Business
  • Verified by Visa
  • Mastercard SecureCode
Details

About the BUC

The NJT5762KNA is a Nisshinbo block up converter (BUC) operating in C-Band, with an output range of 5.85 - 6.425 GHz and an N-type IF interface. Full electrical, mechanical and environmental specifications are listed below.

Key Specifications

BandC-Band
Output FrequencyC-Band: 5.85 - 6.425 GHz
IF ConnectorN-Connector
M&C OptionFSK Communications M&C Option, only for NJT5762 series
DC Power Input ConnectorIF Interface Connector
Power Supply, Operating VoltageAC Power Operation Option, 100 to 240 V AC

Electrical Specifications

Output RF Frequency Range5.85 to 6.425 GHz
Input IF Frequency Range950 to 1,525 MHz
Maximum IF Input Level(without damage)+13 dBm max.
Conversion TypeSingle, fixed L.O.
L.O. Frequency4.9 GHz
Frequency SensePositive
Output Power @ 1dB G.C.P. (P1dB)+40 dBm min. over temperature
IM3@ total power <= +40 dBm - 3 dB
-28 dBc typ., -26 dBc max.
Linear Gain64 dB nom., 58 dB min.
Gain Variation over frequency @ fixed temperature4 dBp-p max. over 575 MHz
2 dBp-p max. over 54 MHz
Gain Stability over temperature @ fixed frequency4 dBp-p max.
2 dBp-p typ.
Requirement for External ReferenceFrequency: 10 MHz (sine-wave)
Input Power: -5 to +5 dBm @ Input port
Phase Noise: -120 dBc/Hz max. @ 100 Hz
-130 dBc/Hz max. @ 1 kHz
-140 dBc/Hz max. @ 10 kHz
L.O. Phase Noise-60 dBc/Hz max. @ 100 Hz
-70 dBc/Hz max. @ 1 kHz
-80 dBc/Hz max. @ 10 kHz
-90 dBc/Hz max. @ 100 kHz
-100 dBc/Hz max. @ 1MHz
Spurious @ Pout = +40 dBmIn-band: -50 dBc max. @ 5.85 to 6.425 GHz
Receive-band: -70 dBm max. @ 3.625 to 4.2 GHz
Out-of-band: -50 dBc max.
Receive Band Noise Density-87 dBm/4kHz max. @ 3.625 to 4.2 GHz
Input Impedance50 ohms nom
Input V.S.W.R.2 : 1 max.
Output V.S.W.R.2 : 1 max.
Output Load V.S.W.R.Recommendation: 1.3 : 1 max.
Non Damage: Infinite : 1
DC Power RequirementVoltage Range: 100 to 240 VAC
*Details are mentioned on Appendix of “Indoor
150W AC/DC Power Supply Unit”.
MuteShut off the HPA in case of L.O. unlocked or no 10
MHz reference signal.
Shut off the HPA in case of L.O. unlocked or no 10 MHz
reference signal (or status of over temperature)
LED IndicatorGREEN: LO locked
RED: LO unlocked
(or no 10 MHz reference signal)
Monitor and ControlInterface: 650kHz FSK Signal on IF Connector
Functions: Monitor:
Tx Output Power / Temperature / Tx Status
/ Alarm (Over temperature
/ L.O. unlock)
Control:
Transmit On/Off
Performance: Tx Output Power:
Detector Range: 15 dB (up to P1dB)
Reading Accuracy: +/- 1.0 dB
*Details are mentioned on Appendix of
“Specifications of Monitor & Control”.
dBc at the IDU and IF signal
ircular
connector models to avoid
temperature which turn out at internal temperatur e of around 120 °C, and the Mute and
Alarm will function at status of over temperature. After the Mute and Alarm of over

Mechanical Specifications

Input InterfaceIF Connector: IF / Ref. / FSK M&C Signal / DC Power Input:
Coaxial Connector, N-type Female - 50 ohms
Output InterfaceWaveguide, CPR-137G (with Groove)
Dimension & Housing219.5 (L) x 175 (W) x 99 (H) mm
[8.64” (L) x 6.89” (W) x 3.90” (H)]
Weight3.2 kg typ.
[7.0 lbs typ.]
CoolingConvection Air Cooling
avoid

Environmental Specifications

Temperature Range (Ambient)Operating: -40 to +55 °C
Storage: -40 to +75 °C
Humidity0 to 100 % RH
Altitude15,000 feet (4,572 m)
Vibration (Survival)5 G [49.03 m/s2] (3 axis, 50 Hz to 2 kHz)
1 mm p-p (3 axis, 5 to 50 Hz)
Shock (Survival)30 G [294.20 m/s2] (3 axis)
Waterproof / Dustproof (IP Code Rating)IP 67
RegulationsEU Directive (CE Marking)
EMC - 2014/30/EU
RoHS - 2011/65/EU + (EU)2015/863
Safety: EN60950-1, EN60950-22
MTBF (by Method of Parts Count Reliability as Design Condition Prediction)120,000 hours and more at +55 °C

Power Supply Unit(PSU) - Electrical Specifications

Input AC Voltage RangeRated Range: 100 to 240 VAC
Absolute Maximum Rating: 90 to 264 VAC
Input AC Frequency Range50/60 Hz
Maximum Input AC Apparent Power200 VA
Output Voltage+48 VDC
Output Voltage Accuracy+/- 10 %
Output Current Range0 to 3.2 A
Maximum Output Power150W
Standby Mode Power10 W max.
Condition: No Connect BUC · No Output DC Power
Efficiency80 % typ. at 120 VAC, full load
Power Factor0.98 typ. at 120 VAC, full load
Output ON/OFF Controla) Rocker Switch on the Front Panel
b) Mode of DC Power Output
Option 1: To keep supplying
Option 2: Synchronization with input
DC voltage on/off
IF Frequency Range950 to 1,700 MHz
IF Input/ Output Impedance50 ohms nom
IF Input/ Output VSWR2 : 1 max.
IF Insertion Loss1.5 dB max.
Input DC Voltage Range+24 / +48 VDC
In case of option 2 in mode of DC power output,
50mA min. is needed from modem.
ProtectionInternal Primary Current Fuse
Short Protection
LED IndicatorDC Output (Power): GREEN: Supply a DC Power to BUC
Fan Alarm: GREEN: Normal Condition
RED: Abnormal Condition
and Fan must be Replaced

Power Supply Unit(PSU) - Mechanical Specifications

AC Input InterfaceIEC320-C14 Inlet
IF Input Interface ConnectorN-type Female Connector, 50 ohms
IF Output Interface ConnectorN-type Female Connector, 50 ohms
CoolingForced-air-cooled by Fan
Dimension & Housing290 (W) x 200 (D) x 44 (H) mm
[11.42” (W) x 7.87” (D) x 1.73” (H) ]
Weight1.6 kg
[3.5 lbs]

Power Supply Unit(PSU) - Environmental Specifications

Temperature Range (Ambient)Operating: 0 to +50 °C
Storage: -30 to +85 °C
HumidityOperating: 30 to 90 %Rh non-condensing
Storage: 10 to 95 %Rh
Vibration (Survival)Non Operation
2 G [19.6 m/s2] Constant
(10 to 55 Hz, Sweep Time: 1 min., 3 axis, 1 hour)
Shock (Survival)20 G [196.1 m/s2]
(3 axis)
RegulationsEU Directive (CE Marking)
EMC - 2014/30/EU
Low Voltage - 2014/35/EU
RoHS - 2011/65/EU, (EU)2015/863
UL Citification
Compliance StandardEN 55022
EN 55024
EN 61000-3-2/3
EN 60950-1 / UL60950-1
EN 62311
MTBF150,000 hours and more at +50 °C
as Design Condition
0 Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Customer Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Flexible Shipping Terms

UPS, FedEx, DHL

Extended Warranty

Contact our agents

Loyalty Program

Additional savings on return customers

24/7 Technical Support

+1.888.218.9394