Nisshinbo
Nisshinbo NJT5762KFMA C-band 10W BUC 5.85 - 6.425 GHz
Product Code:
NJT5762KFMA
Condition:
New
Availability:
YES
Weight:
3.20 KGS
Width:
21.95
(cm)
Height:
9.90
(cm)
Depth:
17.50
(cm)
Request a quote at Contact@orbitalconnect.com or +1.888.315.9545
About the BUC
The NJT5762KFMA is a Nisshinbo block up converter (BUC) operating in C-Band, with an output range of 5.85 - 6.425 GHz and an F-type IF interface. Full electrical, mechanical and environmental specifications are listed below.
Key Specifications
| Band | C-Band |
| Output Frequency | C-Band: 5.85 - 6.425 GHz |
| IF Connector | F-Connector |
| M&C Option | FSK Communications M&C Option, only for NJT5762 series |
| DC Power Input Connector | Circular Connector (MS3102E 12S-3P) |
| Power Supply, Operating Voltage | AC Power Operation Option, 100 to 240 V AC |
Electrical Specifications
| Output RF Frequency Range | 5.85 to 6.425 GHz |
| Input IF Frequency Range | 950 to 1,525 MHz |
| Maximum IF Input Level(without damage) | +13 dBm max. |
| Conversion Type | Single, fixed L.O. |
| L.O. Frequency | 4.9 GHz |
| Frequency Sense | Positive |
| Output Power @ 1dB G.C.P. (P1dB) | +40 dBm min. over temperature |
| IM3 | @ total power <= +40 dBm - 3 dB -28 dBc typ., -26 dBc max. |
| Linear Gain | 64 dB nom., 58 dB min. |
| Gain Variation over frequency @ fixed temperature | 4 dBp-p max. over 575 MHz 2 dBp-p max. over 54 MHz |
| Gain Stability over temperature @ fixed frequency | 4 dBp-p max. 2 dBp-p typ. |
| Requirement for External Reference | Frequency: 10 MHz (sine-wave) Input Power: -5 to +5 dBm @ Input port Phase Noise: -120 dBc/Hz max. @ 100 Hz -130 dBc/Hz max. @ 1 kHz -140 dBc/Hz max. @ 10 kHz |
| L.O. Phase Noise | -60 dBc/Hz max. @ 100 Hz -70 dBc/Hz max. @ 1 kHz -80 dBc/Hz max. @ 10 kHz -90 dBc/Hz max. @ 100 kHz -100 dBc/Hz max. @ 1MHz |
| Spurious @ Pout = +40 dBm | In-band: -50 dBc max. @ 5.85 to 6.425 GHz Receive-band: -70 dBm max. @ 3.625 to 4.2 GHz Out-of-band: -50 dBc max. |
| Receive Band Noise Density | -87 dBm/4kHz max. @ 3.625 to 4.2 GHz |
| Input Impedance | 75 ohms nom. |
| Input V.S.W.R. | 2 : 1 max. |
| Output V.S.W.R. | 2 : 1 max. |
| Output Load V.S.W.R. | Recommendation: 1.3 : 1 max. Non Damage: Infinite : 1 |
| DC Power Requirement | Voltage Range: 100 to 240 VAC *Details are mentioned on Appendix of “Indoor 150W AC/DC Power Supply Unit”. |
| Mute | Shut off the HPA in case of L.O. unlocked or no 10 MHz reference signal. Shut off the HPA in case of L.O. unlocked or no 10 MHz reference signal (or status of over temperature) |
| LED Indicator | GREEN: LO locked RED: LO unlocked (or no 10 MHz reference signal) |
| Monitor and Control | Interface: 650kHz FSK Signal on IF Connector Functions: Monitor: Tx Output Power / Temperature / Tx Status / Alarm (Over temperature / L.O. unlock) Control: Transmit On/Off Performance: Tx Output Power: Detector Range: 15 dB (up to P1dB) Reading Accuracy: +/- 1.0 dB *Details are mentioned on Appendix of “Specifications of Monitor & Control”. dBc at the IDU and IF signal ircular connector models to avoid temperature which turn out at internal temperatur e of around 120 °C, and the Mute and Alarm will function at status of over temperature. After the Mute and Alarm of over |
Mechanical Specifications
| Input Interface | IF Connector: IF / Ref. / FSK M&C Signal / DC Power Input: Coaxial Connector, F-type Female - 75 ohms Circular Connector: DC Power Input: Model: MS3102E 12S-3P Mating connector: MS3106E 12S-3S [MS Connector /MIL -DTL-5015] Assignment: |
| Output Interface | Waveguide, CPR-137G (with Groove) |
| Dimension & Housing | 219.5 (L) x 175 (W) x 99 (H) mm [8.64” (L) x 6.89” (W) x 3.90” (H)] |
| Weight | 3.2 kg typ. [7.0 lbs typ.] |
| Cooling | Convection Air Cooling avoid |
Environmental Specifications
| Temperature Range (Ambient) | Operating: -40 to +55 °C Storage: -40 to +75 °C |
| Humidity | 0 to 100 % RH |
| Altitude | 15,000 feet (4,572 m) |
| Vibration (Survival) | 5 G [49.03 m/s2] (3 axis, 50 Hz to 2 kHz) 1 mm p-p (3 axis, 5 to 50 Hz) |
| Shock (Survival) | 30 G [294.20 m/s2] (3 axis) |
| Waterproof / Dustproof (IP Code Rating) | IP 67 |
| Regulations | EU Directive (CE Marking) EMC - 2014/30/EU RoHS - 2011/65/EU + (EU)2015/863 Safety: EN60950-1, EN60950-22 |
| MTBF (by Method of Parts Count Reliability as Design Condition Prediction) | 120,000 hours and more at +55 °C |
Power Supply Unit(PSU) - Electrical Specifications
| Input AC Voltage Range | Rated Range: 100 to 240 VAC Absolute Maximum Rating: 90 to 264 VAC |
| Input AC Frequency Range | 50/60 Hz |
| Maximum Input AC Apparent Power | 200 VA |
| Output Voltage | +48 VDC |
| Output Voltage Accuracy | +/- 10 % |
| Output Current Range | 0 to 3.2 A |
| Maximum Output Power | 150W |
| Standby Mode Power | 10 W max. Condition: No Connect BUC · No Output DC Power |
| Efficiency | 80 % typ. at 120 VAC, full load |
| Power Factor | 0.98 typ. at 120 VAC, full load |
| Output ON/OFF Control | a) Rocker Switch on the Front Panel b) Mode of DC Power Output Option 1: To keep supplying Option 2: Synchronization with input DC voltage on/off |
| IF Frequency Range | 950 to 1,700 MHz |
| IF Input/ Output Impedance | 75 ohms nom. |
| IF Input/ Output VSWR | 2 : 1 max. |
| IF Insertion Loss | 1.5 dB max. |
| Input DC Voltage Range | +24 / +48 VDC In case of option 2 in mode of DC power output, 50mA min. is needed from modem. |
| Protection | Internal Primary Current Fuse Short Protection |
| LED Indicator | DC Output (Power): GREEN: Supply a DC Power to BUC Fan Alarm: GREEN: Normal Condition RED: Abnormal Condition and Fan must be Replaced |
Power Supply Unit(PSU) - Mechanical Specifications
| AC Input Interface | IEC320-C14 Inlet |
| IF Input Interface Connector | F-type Female Connector, 75 ohms |
| IF Output Interface Connector | F-type Female Connector, 75 ohms |
| Cooling | Forced-air-cooled by Fan |
| Dimension & Housing | 290 (W) x 200 (D) x 44 (H) mm [11.42” (W) x 7.87” (D) x 1.73” (H) ] |
| Weight | 1.6 kg [3.5 lbs] |
Power Supply Unit(PSU) - Environmental Specifications
| Temperature Range (Ambient) | Operating: 0 to +50 °C Storage: -30 to +85 °C |
| Humidity | Operating: 30 to 90 %Rh non-condensing Storage: 10 to 95 %Rh |
| Vibration (Survival) | Non Operation 2 G [19.6 m/s2] Constant (10 to 55 Hz, Sweep Time: 1 min., 3 axis, 1 hour) |
| Shock (Survival) | 20 G [196.1 m/s2] (3 axis) |
| Regulations | EU Directive (CE Marking) EMC - 2014/30/EU Low Voltage - 2014/35/EU RoHS - 2011/65/EU, (EU)2015/863 UL Citification |
| Compliance Standard | EN 55022 EN 55024 EN 61000-3-2/3 EN 60950-1 / UL60950-1 EN 62311 |
| MTBF | 150,000 hours and more at +50 °C as Design Condition |
5 customers are viewing this product
Details
About the BUC
The NJT5762KFMA is a Nisshinbo block up converter (BUC) operating in C-Band, with an output range of 5.85 - 6.425 GHz and an F-type IF interface. Full electrical, mechanical and environmental specifications are listed below.
Key Specifications
| Band | C-Band |
| Output Frequency | C-Band: 5.85 - 6.425 GHz |
| IF Connector | F-Connector |
| M&C Option | FSK Communications M&C Option, only for NJT5762 series |
| DC Power Input Connector | Circular Connector (MS3102E 12S-3P) |
| Power Supply, Operating Voltage | AC Power Operation Option, 100 to 240 V AC |
Electrical Specifications
| Output RF Frequency Range | 5.85 to 6.425 GHz |
| Input IF Frequency Range | 950 to 1,525 MHz |
| Maximum IF Input Level(without damage) | +13 dBm max. |
| Conversion Type | Single, fixed L.O. |
| L.O. Frequency | 4.9 GHz |
| Frequency Sense | Positive |
| Output Power @ 1dB G.C.P. (P1dB) | +40 dBm min. over temperature |
| IM3 | @ total power <= +40 dBm - 3 dB -28 dBc typ., -26 dBc max. |
| Linear Gain | 64 dB nom., 58 dB min. |
| Gain Variation over frequency @ fixed temperature | 4 dBp-p max. over 575 MHz 2 dBp-p max. over 54 MHz |
| Gain Stability over temperature @ fixed frequency | 4 dBp-p max. 2 dBp-p typ. |
| Requirement for External Reference | Frequency: 10 MHz (sine-wave) Input Power: -5 to +5 dBm @ Input port Phase Noise: -120 dBc/Hz max. @ 100 Hz -130 dBc/Hz max. @ 1 kHz -140 dBc/Hz max. @ 10 kHz |
| L.O. Phase Noise | -60 dBc/Hz max. @ 100 Hz -70 dBc/Hz max. @ 1 kHz -80 dBc/Hz max. @ 10 kHz -90 dBc/Hz max. @ 100 kHz -100 dBc/Hz max. @ 1MHz |
| Spurious @ Pout = +40 dBm | In-band: -50 dBc max. @ 5.85 to 6.425 GHz Receive-band: -70 dBm max. @ 3.625 to 4.2 GHz Out-of-band: -50 dBc max. |
| Receive Band Noise Density | -87 dBm/4kHz max. @ 3.625 to 4.2 GHz |
| Input Impedance | 75 ohms nom. |
| Input V.S.W.R. | 2 : 1 max. |
| Output V.S.W.R. | 2 : 1 max. |
| Output Load V.S.W.R. | Recommendation: 1.3 : 1 max. Non Damage: Infinite : 1 |
| DC Power Requirement | Voltage Range: 100 to 240 VAC *Details are mentioned on Appendix of “Indoor 150W AC/DC Power Supply Unit”. |
| Mute | Shut off the HPA in case of L.O. unlocked or no 10 MHz reference signal. Shut off the HPA in case of L.O. unlocked or no 10 MHz reference signal (or status of over temperature) |
| LED Indicator | GREEN: LO locked RED: LO unlocked (or no 10 MHz reference signal) |
| Monitor and Control | Interface: 650kHz FSK Signal on IF Connector Functions: Monitor: Tx Output Power / Temperature / Tx Status / Alarm (Over temperature / L.O. unlock) Control: Transmit On/Off Performance: Tx Output Power: Detector Range: 15 dB (up to P1dB) Reading Accuracy: +/- 1.0 dB *Details are mentioned on Appendix of “Specifications of Monitor & Control”. dBc at the IDU and IF signal ircular connector models to avoid temperature which turn out at internal temperatur e of around 120 °C, and the Mute and Alarm will function at status of over temperature. After the Mute and Alarm of over |
Mechanical Specifications
| Input Interface | IF Connector: IF / Ref. / FSK M&C Signal / DC Power Input: Coaxial Connector, F-type Female - 75 ohms Circular Connector: DC Power Input: Model: MS3102E 12S-3P Mating connector: MS3106E 12S-3S [MS Connector /MIL -DTL-5015] Assignment: |
| Output Interface | Waveguide, CPR-137G (with Groove) |
| Dimension & Housing | 219.5 (L) x 175 (W) x 99 (H) mm [8.64” (L) x 6.89” (W) x 3.90” (H)] |
| Weight | 3.2 kg typ. [7.0 lbs typ.] |
| Cooling | Convection Air Cooling avoid |
Environmental Specifications
| Temperature Range (Ambient) | Operating: -40 to +55 °C Storage: -40 to +75 °C |
| Humidity | 0 to 100 % RH |
| Altitude | 15,000 feet (4,572 m) |
| Vibration (Survival) | 5 G [49.03 m/s2] (3 axis, 50 Hz to 2 kHz) 1 mm p-p (3 axis, 5 to 50 Hz) |
| Shock (Survival) | 30 G [294.20 m/s2] (3 axis) |
| Waterproof / Dustproof (IP Code Rating) | IP 67 |
| Regulations | EU Directive (CE Marking) EMC - 2014/30/EU RoHS - 2011/65/EU + (EU)2015/863 Safety: EN60950-1, EN60950-22 |
| MTBF (by Method of Parts Count Reliability as Design Condition Prediction) | 120,000 hours and more at +55 °C |
Power Supply Unit(PSU) - Electrical Specifications
| Input AC Voltage Range | Rated Range: 100 to 240 VAC Absolute Maximum Rating: 90 to 264 VAC |
| Input AC Frequency Range | 50/60 Hz |
| Maximum Input AC Apparent Power | 200 VA |
| Output Voltage | +48 VDC |
| Output Voltage Accuracy | +/- 10 % |
| Output Current Range | 0 to 3.2 A |
| Maximum Output Power | 150W |
| Standby Mode Power | 10 W max. Condition: No Connect BUC · No Output DC Power |
| Efficiency | 80 % typ. at 120 VAC, full load |
| Power Factor | 0.98 typ. at 120 VAC, full load |
| Output ON/OFF Control | a) Rocker Switch on the Front Panel b) Mode of DC Power Output Option 1: To keep supplying Option 2: Synchronization with input DC voltage on/off |
| IF Frequency Range | 950 to 1,700 MHz |
| IF Input/ Output Impedance | 75 ohms nom. |
| IF Input/ Output VSWR | 2 : 1 max. |
| IF Insertion Loss | 1.5 dB max. |
| Input DC Voltage Range | +24 / +48 VDC In case of option 2 in mode of DC power output, 50mA min. is needed from modem. |
| Protection | Internal Primary Current Fuse Short Protection |
| LED Indicator | DC Output (Power): GREEN: Supply a DC Power to BUC Fan Alarm: GREEN: Normal Condition RED: Abnormal Condition and Fan must be Replaced |
Power Supply Unit(PSU) - Mechanical Specifications
| AC Input Interface | IEC320-C14 Inlet |
| IF Input Interface Connector | F-type Female Connector, 75 ohms |
| IF Output Interface Connector | F-type Female Connector, 75 ohms |
| Cooling | Forced-air-cooled by Fan |
| Dimension & Housing | 290 (W) x 200 (D) x 44 (H) mm [11.42” (W) x 7.87” (D) x 1.73” (H) ] |
| Weight | 1.6 kg [3.5 lbs] |
Power Supply Unit(PSU) - Environmental Specifications
| Temperature Range (Ambient) | Operating: 0 to +50 °C Storage: -30 to +85 °C |
| Humidity | Operating: 30 to 90 %Rh non-condensing Storage: 10 to 95 %Rh |
| Vibration (Survival) | Non Operation 2 G [19.6 m/s2] Constant (10 to 55 Hz, Sweep Time: 1 min., 3 axis, 1 hour) |
| Shock (Survival) | 20 G [196.1 m/s2] (3 axis) |
| Regulations | EU Directive (CE Marking) EMC - 2014/30/EU Low Voltage - 2014/35/EU RoHS - 2011/65/EU, (EU)2015/863 UL Citification |
| Compliance Standard | EN 55022 EN 55024 EN 61000-3-2/3 EN 60950-1 / UL60950-1 EN 62311 |
| MTBF | 150,000 hours and more at +50 °C as Design Condition |