ETI Tracon GPT 230 Dual Channel Heat Trace Temperature Controller
THE GPT 230 DUAL CHANNEL HEAT–TRACE CONTROL is a dual–point microprocessor–based heat–trace control thermostat. It is ideal for applications which require two independent heater–control Channels with Ground–Fault Equipment Protection (GFEP). Ideal uses include freeze protection, hot water temperature maintenance, grease line trace, tank heating, and other temperature monitoring and control applications. The GPT 230 Heat–Trace Control operates from the heater’s power source. A universal power supply allows the GPT 230 to operate from 100 V ac to 277 V ac. It can independently or jointly control two resistive loads up to 30 amps each.
ADJUSTABLE TEMPERATURE SETPOINT AND ALARMS
The temperature setpoints are adjustable from −99.9 °F to 999 °F (−73.3 °C to 537.7 °C) to a tenth degree resolution.
SENSOR INPUTS
The GPT 230 comes with two 100K ohm Thermistor temperature sensors with 20 ft. jacketed cables. The included sensors have an operating range of 40 °F to 230 °F (−40 °C to 110 °C). The GPT 230 can also use 3-wire RTD sensors for systems requiring high–temperature sensing. Two temperature sensor inputs are provided, and the channels can operate independently or from one sensor.
PRECISION MONITORING AND CONTROL
The GPT 230 monitors temperature, load current, and ground leakage current. Alarms include high temperature, low temperature, high load current, low load current, ground fault, sensor fault, internal fault, and power fail. These alarms are easy to adjust and observe from the front panel. The GPT 230 can be set to energize or de-energize the heaters during a sensor fault.
GROUND–FAULT EQUIPMENT PROTECTION
The GPT 230 Heat–Trace Control includes integral GFEP for each channel. This eliminates the extra expenses associated with having to provide separate GFEP components in the circuit panel. The GPT 230 normally disconnects power immediately to the affected zone when ground fault current exceeds the set value. But if it is set to Fire Protect mode, for critical fire protection systems, then it will generate the alarm but power will be maintained to prevent freezing.
AUTOMATIC GFEP CIRCUIT SELF–TEST
To ensure continued safe operation, the GPT 230 performs a self–test of the GFEP circuits when power is first applied, along with a load ground fault test, and this repeats periodically thereafter at an adjustable interval.
THE GPT 230 DUAL CHANNEL HEAT–TRACE CONTROL is a dual–point microprocessor–based heat–trace control thermostat. It is ideal for applications which require two independent heater–control Channels with Ground–Fault Equipment Protection (GFEP). Ideal uses include freeze protection, hot water temperature maintenance, grease line trace, tank heating, and other temperature monitoring and control applications. The GPT 230 Heat–Trace Control operates from the heater’s power source. A universal power supply allows the GPT 230 to operate from 100 V ac to 277 V ac. It can independently or jointly control two resistive loads up to 30 amps each.
ADJUSTABLE TEMPERATURE SETPOINT AND ALARMS
The temperature setpoints are adjustable from −99.9 °F to 999 °F (−73.3 °C to 537.7 °C) to a tenth degree resolution.
SENSOR INPUTS
The GPT 230 comes with two 100K ohm Thermistor temperature sensors with 20 ft. jacketed cables. The included sensors have an operating range of 40 °F to 230 °F (−40 °C to 110 °C). The GPT 230 can also use 3-wire RTD sensors for systems requiring high–temperature sensing. Two temperature sensor inputs are provided, and the channels can operate independently or from one sensor.
PRECISION MONITORING AND CONTROL
The GPT 230 monitors temperature, load current, and ground leakage current. Alarms include high temperature, low temperature, high load current, low load current, ground fault, sensor fault, internal fault, and power fail. These alarms are easy to adjust and observe from the front panel. The GPT 230 can be set to energize or de-energize the heaters during a sensor fault.
GROUND–FAULT EQUIPMENT PROTECTION
The GPT 230 Heat–Trace Control includes integral GFEP for each channel. This eliminates the extra expenses associated with having to provide separate GFEP components in the circuit panel. The GPT 230 normally disconnects power immediately to the affected zone when ground fault current exceeds the set value. But if it is set to Fire Protect mode, for critical fire protection systems, then it will generate the alarm but power will be maintained to prevent freezing.
AUTOMATIC GFEP CIRCUIT SELF–TEST
To ensure continued safe operation, the GPT 230 performs a self–test of the GFEP circuits when power is first applied, along with a load ground fault test, and this repeats periodically thereafter at an adjustable interval.